Chapter 1 Product Overview

Services Modules

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

LEDs on the 18/4-Port Multiservice Module

Table 1-15describes the LEDs for the 18/4-port Multiservice module.

Table 1-15

LEDs for the Cisco MDS 9000 Family 18/4-Port Multiservice Modules

 

 

 

 

 

LED

Status

 

Description

 

 

 

 

 

Status

Green

 

All diagnostics pass. The module is operational (normal

 

 

 

initialization sequence).

 

 

 

 

 

 

Orange

 

One of the following occurs or occurred:

 

 

 

The module is booting or running diagnostics (normal

 

 

 

initialization sequence).

 

 

 

The inlet air temperature of the system exceeded the

 

 

 

maximum system operating temperature limit (a minor

 

 

 

environmental warning). To ensure maximum product

 

 

 

life, you should immediately correct the environmental

 

 

 

temperature and restore the system to normal operation.

 

 

 

 

 

 

Red

 

One of the following occurred:

 

 

 

The diagnostic test failed. The module is not operational

 

 

 

because a fault occurred during the initialization

 

 

 

sequence.

 

 

 

The inlet air temperature of the system exceeded the safe

 

 

 

operating temperature limits of the card (a major

 

 

 

environmental warning). The card shut down to prevent

 

 

 

permanent damage.

 

 

 

 

 

Link

Solid

 

Link is up.

 

green

 

 

 

 

 

 

 

 

 

Solid

 

Link is disabled by software.

 

yellow

 

 

 

 

 

 

 

 

Flashing

A fault condition exists.

 

yellow

 

 

 

 

 

 

 

 

 

Off

 

No link.

 

 

 

 

 

 

 

Cisco MDS 9500 Series Hardware Installation Guide

 

 

 

 

 

 

OL-17467-02

 

 

1-43

 

 

 

 

 

Page 65