Chapter 1 Product Overview
Services Modules
Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .
LEDs on the 18/4-Port Multiservice Module
Table 1-15 describes the LEDs for the 18/4-port Multiservice module.
Table | LEDs for the Cisco MDS 9000 Family | |||
|
|
|
|
|
LED | Status |
| Description | |
|
|
|
|
|
Status | Green |
| All diagnostics pass. The module is operational (normal | |
|
|
| initialization sequence). | |
|
|
|
|
|
| Orange |
| One of the following occurs or occurred: | |
|
|
| • The module is booting or running diagnostics (normal | |
|
|
| initialization sequence). | |
|
|
| • The inlet air temperature of the system exceeded the | |
|
|
| maximum system operating temperature limit (a minor | |
|
|
| environmental warning). To ensure maximum product | |
|
|
| life, you should immediately correct the environmental | |
|
|
| temperature and restore the system to normal operation. | |
|
|
|
|
|
| Red |
| One of the following occurred: | |
|
|
| • The diagnostic test failed. The module is not operational | |
|
|
| because a fault occurred during the initialization | |
|
|
| sequence. | |
|
|
| • The inlet air temperature of the system exceeded the safe | |
|
|
| operating temperature limits of the card (a major | |
|
|
| environmental warning). The card shut down to prevent | |
|
|
| permanent damage. | |
|
|
|
|
|
Link | Solid |
| Link is up. | |
| green |
|
|
|
|
|
|
|
|
| Solid |
| Link is disabled by software. | |
| yellow |
|
|
|
|
|
|
| |
| Flashing | A fault condition exists. | ||
| yellow |
|
|
|
|
|
|
|
|
| Off |
| No link. | |
|
|
|
|
|
|
| Cisco MDS 9500 Series Hardware Installation Guide |
|
| |
|
|
| |||
|
|
|
| ||
|
|
|
|