Chapter 2 Installing the Cisco MDS 9500 Series
Grounding the Chassis
Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .
Figure 2-12 ESD Ground Location on the Cisco MDS 9513 Chassis (Rear)
144509
1 2
1
ESD plug
2
ESD socket
Caution All power supplies must be grounded. The receptacles of the AC power cables used to provide power to the chassis must be the grounding type, and the grounding conductors should connect to protective earth ground at the service equipment. For a Cisco MDS 9509 Director with a DC power supply, a grounding cable must be connected to the terminal block. For a Cisco MDS 9506 Director with a DC power supply, the chassis ground is required.
Figure 2-13 shows the system ground location on the Cisco MDS 9509 chassis.
|