Cisco Systems MDS 9500 Series manual Table D-8 Specifications for Cisco MDS 9513 Power Supplies

Models: MDS 9500 Series

1 288
Download 288 pages 59.22 Kb
Page 219
Image 219

Appendix D Technical Specifications

Power Specifications for the Cisco MDS 9513 Director

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

Two AC power connection @ 220 VAC = 6000 W output

If a 110 VAC input is chosen, a 110-VAC power cord (CAB-7513AC=) must be ordered separately.

Note Power output does not include the power used by the individual modules used in the chassis.

Table D-8lists the specifications for the Cisco MDS 9513 power supplies.

Table D-8 Specifications for Cisco MDS 9513 Power Supplies

Description

Specification

6000-W AC Power Supply

Type

Autoranging input with power factor corrector.

 

 

Voltage

100 to 240 VAC (±10%).

 

 

Current rating

16 A maximum at 100 to 120 VAC and 2900-W output.

 

16 A maximum at 200 to 240 VAC and 6000-W output.

 

 

Frequency

50 to 60 Hz (nominal) (±3 Hz for full range).

 

 

Output capacity

One AC power connection @110 VAC = No output

 

Two AC power connection @110 VAC = 2900 W output

 

One AC power connection @ 220 VAC = 2900 W output

 

One AC power connection @110 VAC and one AC power connection

 

@ 220 VAC = 2900 W output

 

Two AC power connection @ 220 VAC = 6000 W output

 

 

Output voltage at 110/120

3.3 V at 10 A, 50 V at 57 A

 

 

Output voltage at 200/240

3.3 V at 10A, 50 V at 119 A

 

 

Component Power Requirements and Heat Dissipation for the Cisco MDS 9513 Director

Consider heat dissipation when sizing the air-conditioning requirements for an installation. The power and heat associated with a Cisco MDS 9513 Director varies based upon the following considerations:

Power supply type

Switching module type and number of switching modules installed

Average switching traffic levels

Table D-9lists the power requirements and heat dissipation for the components of the Cisco MDS 9513 Director.

Note Unless noted otherwise, the data listed in Table D-9is based on worst-case conditions. Typical numbers are approximately 30 percent below the numbers listed here.

Cisco MDS 9500 Series Hardware Installation Guide

 

OL-17467-02

D-7

 

Page 219
Image 219
Cisco Systems MDS 9500 Series manual Table D-8 Specifications for Cisco MDS 9513 Power Supplies