Cisco Systems MDS 9500 Series manual Maintaining a Caching Services Module

Models: MDS 9500 Series

1 288
Download 288 pages 59.22 Kb
Page 130
Image 130

Chapter 2 Installing the Cisco MDS 9500 Series

Maintaining a Caching Services Module

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

Note Ensure the ejector levers are completely closed before tightening the captive screws. Failure to completely seat the module in the backplane connector can result in error messages.

e.Tighten the two captive screws on the module to 8 in-lb.

Maintaining a Caching Services Module

Caution Maintenance must be performed only by qualified service personnel.

Note A minimum of two CSMs in each fabric are required for redundancy and data backup.

This section provides the following information:

Maintaining the Batteries on the Caching Services Module, page 2-50

Maintaining the Disk Drives on the Caching Services Module, page 2-51

Maintaining the Batteries on the Caching Services Module

The CSM batteries last approximately three years. The following message displays in the system log when a battery fails:

Dec 5 17:14:36 sw-90.21% SVC_BATTERY-SLOT8-4-BATTERY_CAPACITY_LOW:

Battery capacity is below the required threshold.

If this message is displayed, contact your support provider for assistance. If a battery fails, the CSM must be replaced. The other CSMs in the fabric contain the same data, and they continue providing caching services during the replacement period.

Caution The CSM batteries are shipped fully charged and should be handled accordingly.

Warning Do not touch or bridge the metal contacts on the battery. Unintentional discharge of the batteries can cause serious burns. Statement 341

Warning Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040

The batteries are automatically charged on a periodic basis with an SMBus-compliant Level III smart charger located on the CSM. The smart charger measures the charge and recharges the battery to full if it is less than 90 percent of capacity.

 

Cisco MDS 9500 Series Hardware Installation Guide

2-50

OL-17467-02

Page 130
Image 130
Cisco Systems MDS 9500 Series manual Maintaining a Caching Services Module