Bryant FH4B manual Smart Heat, Estimated Sound Power Level dBA

Models: FH4B

1 12
Download 12 pages 140 b
Page 8
Image 8

SMART HEAT

 

 

 

 

INTERNAL

 

 

HEATER

KW

 

STAGES

CIRCUIT

FAN COIL SIZE

HEATING CAP. **

PART NO.

@ 240V

VOLTS/PHASE

(KW OPERATING)

PROTECTION

USED WITH

@ 230V

KFCEH0101H10

10

230/1

3, 6, 9

None‡

001, 002

31,400

KFCEH0201H15

15

230/1

3, 8, 11, 15

Fuse

001–003

47,100

KFCEH0301H20

20

230/1

5, 10, 15, 20

Fuse

002–004

62,800

* Field convertible to 1 phase.

KFAEH2501N09 is field convertible to 3 phase.

Single point wiring kit required for these heaters in Canada. ** Blower motor heat not included.

When using units with 20-, 24-, and 30-kw electric heaters, maintain a 1-in. clearance from combustible materials to discharge plenum and ductwork, and maintain a distance of 36 in. from the unit. Use an accessory downflow base to maintain proper clearance on downflow installations.

Use flexible connectors between ductwork and unit to prevent transmission of vibration. When electric heater is installed, use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier.

ESTIMATED SOUND POWER LEVEL (dBA)

 

CONDITIONS

 

 

OCTAVE BAND CENTER FREQUENCY*

 

 

UNIT

 

Ext Static

 

 

 

 

 

 

 

SIZE

CFM

Pressure

63

125

250

500

1000

2000

4000

FH4-001

800

0.25

66.0

62.0

58.0

55.0

53.0

51.0

47.0

FH4-002

1200

0.25

67.8

63.8

59.8

56.8

54.8

52.8

48.8

FH4-003

1600

0.25

69.0

65.0

61.0

58.0

56.0

54.0

50.0

FH4-004

2000

0.25

70.0

66.0

62.0

59.0

57.0

55.0

51.0

*Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p. 52.7