CONTENTS |
|
Warranty | 2 |
Introduction | 3 |
User Notices | 4 |
Electrical Requirements | 5 |
Plumbing Requirements | 6 |
Initial | 6 |
Initial | 7 |
OPERATING CONTROLS | 8 |
ADJUST DISPENSE VOLUME | 8 |
Programming (H5E, H5X, | 9 |
Programming (H5 Element) | 11 |
Draining the Dispenser | 14 |
Cleaning | 14 |
INTRODUCTION
This equipment heats and dispenses water on demand for beverages and cooking purposes. It has a panel above the faucet that indicates the status of the dispenser. This equipment is for indoor use, either
Brew water temperature is factory set at 200° F (93.3° C) Areas of high altitude will require lowering this tempera- ture to prevent boiling. This chart should be used as a guide when readjusting the brew water temperature.
Altitude | Boiling point | Recommended | ||
| of water | water temperature | ||
(Feet) | ° F | ° C | ° F | ° C |
|
|
|
|
|
213.8 | 101.0 | 200 | 93.3 | |
212.9 | 100.5 | 200 | 93.3 | |
0 | 212.0 | 100.0 | 200 | 93.3 |
500 | 211.1 | 99.5 | 200 | 93.3 |
1000 | 210.2 | 99.0 | 200 | 93.3 |
1500 | 209.3 | 98.5 | 200 | 93.3 |
2000 | 208.4 | 98.0 | 200 | 93.3 |
2500 | 207.4 | 97.4 | 200 | 93.3 |
3000 | 206.5 | 96.9 | 199 | 92.8 |
3500 | 205.6 | 96.4 | 198 | 92.2 |
4000 | 204.7 | 95.9 | 197 | 91.7 |
4500 | 203.8 | 95.4 | 196 | 91.1 |
5000 | 202.9 | 94.9 | 195 | 90.6 |
5500 | 201.9 | 94.4 | 195 | 90.6 |
6000 | 201.0 | 93.9 | 194 | 90.0 |
6500 | 200.1 | 93.4 | 193 | 89.4 |
7000 | 199.2 | 92.9 | 192 | 88.9 |
7500 | 198.3 | 92.4 | 191 | 88.3 |
8000 | 197.4 | 91.9 | 190 | 87.8 |
8500 | 196.5 | 91.4 | 189 | 87.2 |
9000 | 195.5 | 90.8 | 188 | 86.7 |
9500 | 194.6 | 90.3 | 187 | 86.1 |
10000 | 193.7 | 89.8 | 186 | 85.6 |
3 | 46819 043012 |
|