Bunn 10420 PROGRAMMING - H5-ELEMENT, Adjusting temperature, Program lockout switch, Continued

Models: 10889 10267 10420 44306 10010 39338.0001 39338

1 14
Download 14 pages 62.4 Kb
Page 11
Image 11
PROGRAMMING - H5-ELEMENT

PROGRAMMING - H5-ELEMENT

Adjusting temperature:

The switch must be in the “SET” position in order to access the program modes.

1.Press and hold “TEMP” button until display flashes.

2.While display is flashing, press and release the

(+) to increase or (-) to decrease temperature. NOTE: (Starting with software version 0.06)

If unit is “E” model, temp will stop at 210°F (99°C). If unit is “X” model, temp display will jump from 210°F (99°C) to 212°F (100°C).

Refer to chart on page 3 and adjust temperature requirements according to altitude.

Program lockout switch:

The switch must be in the “SET” position in order to access the program modes.

1.Disconnect the dispenser from the power source.

2.Remove the 4-40 screws and the top cover.

3.Use a small screwdriver to move switch to set position.

4.Install top cover, connect dispenser to power source.

SET

LOCK

Manual Energy Saver Mode:

The energy save mode will allow the tank temperature to drop down to 140°F (60°C).

1.Simultaneously press and release the (+) and (-) to “manually” activate energy save mode.

2.The display will alternately flash between 140 and the current temperature to indicate it is in the energy save mode.

3.Repeat procedure to exit energy save mode.

Step forward

Step backward

Programming the dispenser:

1.Press and hold upper hidden button (bottom center of “BUNN” logo) until “P1” is displayed.

Continued

11

46819 061212

 

Page 11
Image 11
Bunn 10420 PROGRAMMING - H5-ELEMENT, Adjusting temperature, Program lockout switch, Manual Energy Saver Mode, Continued