SERVICE (cont.)

ON/OFF SWITCH-TB6/Q (Sweetner ½ Batch Option-TB3/Q)

 

 

WHI/VIO

 

BLACK

 

PINK

 

optional

P/N 03356.0003

½ batch

GRAY

Non Lighted

Optional

 

 

½ batch

FIG. 15-1 NON LIGHTED ON/OFF SWITCH

FULL/OFF/HALF-TB3/TB3Q

Location:

WHI/VIO

The switch is located on the front control panel.

 

Test Procedure:

WHITE

1. Disconnect the brewer from the power source.

 

2. Disconnect the wires from switch terminals.

BRN/WHI

3. Check for continuity across the center and right

 

and across center and left terminals in rows one

WHI/GRN

through four when the switch is in the oposite

 

position.

BLACK

 

If continuity is not present as described, replace the

WHI/VIO

switch.

UNSWEET/OFF/SWEET-TB3/TB3Q

If continuity is present as described, replace the wires

w/SWEETENER & EMPTY DETECT

the switch is operating properly.

 

Removal and Replacement:

WHI/VIO

1. Remove the wires from the switch terminals.

 

2. Remove the clips on the switch bezel inside the

 

hood and gently push the switch through the

YELLOW

opening.

 

3. Push the new switch into the opening from inside

BLACK

the hood and secure into place by pressing the

bezel through the front of the hood. Make sure

 

the clips on the switch bezel are locked around

 

the switch housing and spread the clips to hold

BRN/BLK

the switch captive in the hood.

LEFT/OFF/RIGHT-TB6

4. Refer to FIG. 15-2 when reconnecting the wires.

 

 

FIG. 15-2 ON/OFF SWITCH TERMINALS