SERVICE (cont.)
VACUUM/SUPPLY PUMP ASSEMBLY
P1560
FIG. 16 VACUUM/SUPPLY PUMP ASSEMBLY
Location:
The vacuum/supply pumps are located inside the autofill box.
Test Procedure:
1.Disconnect the dispenser from the power source.
2.Disconnect the white wire from the pump lead and the yellow, orange or red wire from the other lead.
3.Check the voltage across the white wire and yellow, orange or red wire with a voltmeter. Connect the dispenser to the power source. Push the pump (flavor) switch for the pump to be tested. The indication must be :
a)120 volts ac for two wire 120 volt models.
b)200 to 240 volts ac for two wire 200 or 240 volt
models.
If voltage is present as described, replace the pump. If voltage is not present as described, refer to the wiring diagrams and check the main wiring harness.
Pump Removal and Replacement:
1.Disconnect the wires from the pump leads.
2.Disconnect the input and output tubes.
3.Remove the four thumb screws securing the pump head to the pump body, discard pump head with tubes.
4.Remove the two
5.Remove the two
6.Remove pump body and discard.
7.Install new pump assembly on the pump mounting bracket and secure with two
8.Remove the four thumb screws securing the new pump head with hoses to the new pump body.
9.Using two
10.Using two
11.Install new pump head with hoses to the rear of the pump body and secure with four thumb screws.
12.Connect the input and output tubes using new hose clamps.
13.Refer to Fig 17 and reconnect the wires.
WHI from Main Harness |
|
YEL from Pump Switch #1 |
|
WHI from Pump #1 |
|
ORN from Pump Switch #2 |
|
WHI from Pump #2 |
|
RED from Pump Switch #3 |
|
FIG. 17 VACUUM/SUPPLY PUMP TERMINALS | P1526 |
| |
13 | 28791.1 011500 |
|