TROUBLESHOOTING (cont.)
PROBLEM | PROBABLE CAUSE | REMEDY |
Product will not dispense | 1. Empty product container | Replace or refill |
2.No power or incorrect voltage to the dispenser
3.Signal cable unplugged
4.Hopper is full
5.Fuse and fuse holder
(A1) Check the outlet for 120 volts on two wire 120 volt dispenser.
(A2) Check the outlet for 200 volts or 240 volts ac for two wire 200 volt or 240 volt dispensers.
(B)Check circuit breakers or fuses. Signal cable must be plugged in.
Product must not be touching probes to fill.
Refer to Service - Fuse and Fuse Holder for test procedures. See page 8
Motor thermal cutout (motor stops running)
6. | Main ON/OFF switch | Refer to Service - Main ON/OFF |
|
| Switch for testing procedure. See |
|
| page 9 |
7. Probe box LOW/OFF/HIGH switch- | Refer to Service - Probe System. | |
es |
| See page 10 |
8. | Circuit board | Refer to Service - Circuit Board for |
|
| testing procedures. See page 7 |
9. | Vacuum switches | Refer to Service - Vacuum Switches |
|
| for testing procedures. See page 14 |
10. Vacuum/Supply pump | Refer to Service - Vacuum/ Supply | |
|
| Pump for testing procedures. See |
|
| page 12 |
1. | Motor over heats | The thermal switch will reset, but |
|
| requires up to 30 minutes of cooling |
|
| time. See NOTE below. |
NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time.