Bunn Electrical Specifications, Electrical Hookup, BUNN Espress, ES2A/ES2SA, Red Blk Grn

Models: ES2SA

1 35
Download 35 pages 6.3 Kb
Page 9
Image 9
ELECTRICAL

BUNN Espress™

ELECTRICAL

ES•2A™/ES•2SA™

ELECTRICAL SPECIFICATIONS

This brewer requires a 2-wire grounded service rated 208 to 240 volts ac, 20 amp, single phase, 60

Hz.

ELECTRICAL HOOKUP

CAUTION: Improper installation will damage electronic components.

1.An electrician must provide electrical service as specified.

2.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3.The plug for the brewer is to be supplied by the installer.

4.Attach the plug to the brewer cordset as shown below:

L1ELECTRICAL SPECIFICATIONS

240V or 208V

L2ELECTRICAL HOOKUP

GndL1

Red

Blk

Grn

From brewe

P-140

5.Attach wires from pump cordset to terminal block located on pump motor as shown below:

Brn

Blu

Terminal

block

Cover

Grn/Yel

Blu

Blk

Grommet Compression nut

P-141

NOTE: Wiring going into the terminal block must be tinned with solder to insure proper connection.

Warning: The brewer and pump must be electrically grounded. Do not assume that a plumbing line will provide an adequate ground.

7

Page 9
Image 9
Bunn Electrical Specifications, Electrical Hookup, BUNN Espress, ES2A/ES2SA, L1 240V or L2 Gnd, Red Blk Grn