Bunn HC-2 HC-3 TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, volts across the black and

Models: HC-2 HC-3

1 38
Download 38 pages 32.53 Kb
Page 7
Image 7

TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Product will not dispense

1. No water

Water lines and valves to the

 

 

dispenser must be open.

 

2. No power or incorrect voltage to

(A1) Check the terminal block for

 

the dispenser

120 volts across the black and

 

 

white terminals on two wire 120

 

 

volt dispenser.

 

 

(A2) Check the terminal block for

 

 

120 volts across the red and

 

 

white terminal and the black and

 

 

white terminal on three wire

 

 

120/240 volt dispenser.

 

 

(A3) Check the terminal block for

 

 

240 volts across the white and

 

 

black terminal on two wire 240

 

 

volt dispenser.

 

 

(B) Check circuit breakers or

 

 

fuses.

 

3. Dispense switch

Refer to Service - Dispense

 

 

Switch for testing procedure.

 

 

See page 18

 

4. Dispense solenoid valve

Refer to Service - Dispense

 

(Hot or Cold)

solenoid valve for testing proce-

 

 

dures. See page 30 or 31

 

5. Solenoid valve (Inlet)

Refer to Service - Solenoid Valve

 

 

(Inlet) for testing procedures.

 

 

See page 32

 

6. Level control board and probe

Refer to Service - Level Control

 

 

Board and Probe for testing

 

 

procedures. See page 26

 

7. Overflow protection switch

Refer to Service - Overflow

 

 

protection switch for testing

 

 

procedures. See page 28

 

8. Auger drive

Refer to Service - Auger Drive.

 

 

See page 12

7

27591 031597

 

Page 7
Image 7
Bunn HC-2 HC-3 service manual TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, volts across the black and