ELECTRICAL REQUIREMENTS

ELECTRICAL REQUIREMENTS

Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.

WARNING - The brewer must be disconnected from the power source until specified.

WARNING - The power cord must be UL Listed, Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, Rated 90° C, and the attachment plug cap must be UL Listed, in order to avoid a hazard. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain Relief to end of the Attachment Plug Cap).

L2 RED

L2 RED

 

L2

WHITE

NEUTRAL WHITE

NEUTRAL

N

 

L1 BLACK

L1 BLACK L1

GREEN

120/208-240V 3 WIRE + GROUNDDUAL VOLT240V 2 WIRE + GROUND230V 2 WIRE + GROUND G

POWER CORD

WHITE

NEUTRAL WHITE

NEUTRAL

N

 

L1 BLACK

L1 BLACK L1

 

GREEN

ELECTRICAL HOOK-UP (All Models)Manual backgroundManual backgroundManual backgroundManual background G

POWER CORD

120/208-240V 3 WIRE + GROUND

120V 2 WIRE + GROUND

DUAL VOLT

TOGGLE SWITCH

L2 RED

L2 RED

POWER CORD

 

L2

 

L1 BLACK

L1 BLACK L1

 

 

 

 

 

GREEN

 

G

 

240V 2 WIRE + GROUND

L2 RED

NEUTRAL BLUE

POWER CORD

 

N

 

L1 BLACK

L1 BROWN L1

 

 

 

GREEN/YELLOW

Manual backgroundManual background G

230V 2 WIRE + GROUND

ELECTRICAL HOOK-UP (All Models)

CAUTION – Improper electrical installation will damage electronic components. Damage caused by incor- rect electrical connections is not covered by warranty.

1.An electrician must provide electrical service.

2.Determine the available on-site electrical service.

3.(DV models only) Select the desired unit voltage based on the available on-site electrical service.

4.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

5.Remove the front access panel to gain access to the terminal block.

6.Feed the power cord through the strain relief and connect it to the terminal block(s).

7.Connect the power cord to the terminal block as shown.

8.Before proceeding, verify the voltage at the field wiring terminal block.

9.(DV models only) Set voltage switch to the appropriate position and replace the access panel.