Bunn IMIX -5S+A Running A Rinse Sequence, DISPENSER USE - Self Serve, Draining The Hotwater Tank

Models: IMIX -3S+A IMIX -5S+A

1 13
Download 13 pages 29.88 Kb
Page 6
Image 6

RUNNING A RINSE SEQUENCE

1.Place the Normal/Program/Rinse switch (page 9) in the “rinse” position.

2.Sequentially at each position, press all of the dispense switches. The dispenser will run for 10 seconds with the hopper(s) disabled.

3.As each position is rinsed, the LCD display will show which position is being rinsed and count down from 10 sec- onds.

4.After all positions have been rinsed, return the Normal/Program/Rinse switch to the “Normal” position.

DISPENSER USE - Self Serve

1.Simply place a cup on the drip tray beneath the desired dispensing tip.

2.Press the button to froth and dispense the beverage.

3.Release the button when the cup is approximately 3/4 full and allow the mixing chamber to drain. Note - The mixing chamber must drain at the end of each dispense.

DISPENSER USE - Portion Control

1.Simply place a cup on the drip tray beneath the desired dispensing tip.

2.Press the dispense button momentarily, then release.

3.Let the mixing chamber completely drain before removing cup.

HOPPER DISPENSE RATE OF PRODUCT

The hopper dispense rates are preset at the factory. With 22 tooth gear and auger wire, the preset dispense rate is approximately 3 to 5 grams per second. With 30 tooth gear and auger wire, the preset dispense rate is approximately 5 to 7 grams per second. The hopper dispense rates can be individually programmed to a range of dispense rates from approximately 1.5 to 12 grams per second, by following the procedures described in Programming Modes.

DRAINING THE HOTWATER TANK

CAUTION - The dispenser must be disconnected from the power source throughout these steps

1.Disconnect the dispenser from the power source.

2.Shut off and disconnect the incoming water supply.

3.Remove the drip tray and access panels below the door.

4.Pull the clamped end of the silicone tube out of the dispenser and direct it into a drain or a container large enough to hold the volume of water in the tank (7.3 gal for IMIX-5 and 4.4 gal for IMIX-3).

5.Make certain the shut off clamp is locked tightly on the tube, then remove the snap type clamp and plug from end of tube.

6.Carefully release the shut off clamp to let the water drain from the tank.

NOTE - The dispenser must be refilled using the INITIAL FILL & HEAT steps before reconnecting to the power source.

DOOR GRAPHIC AND LENS INSTALLATION

Remove the clear lens from the door of the machine. Place the door graphic into position and reinstall the clear lens over the door graphic.

PREVENTIVE MAINTENANCE

Bunn-O-Matic®Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic®Corporation at 1-800-286-6070.

NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.

Cycle

Item

Part Number

(months)

6

Mixing Chamber Kit

32906.0001

 

 

 

 

3 or as

Whipper Shaft Seal Kit

26356.1000

needed

 

 

6

38987 120513

Page 6
Image 6
Bunn IMIX -5S+A, IMIX -3S+A Running A Rinse Sequence, DISPENSER USE - Self Serve, DISPENSER USE - Portion Control