ELECTRICAL REQUIREMENTS
CAUTION: The dispenser must remain disconnected from the power source until specified in Electrical Hook- Up.
The
The
These dispensers can be Field Wired for 208 or 240 volt applications. This requires a 2 or
NOTE: The internal terminal block must be rewired for 208/240 applications, (see Optional Field Wiring Diagram).
FIELD WIRING TERMINAL BLOCK DIAGRAM
Models without Master ON/OFF Switch
|
| HEATER RED |
|
|
|
|
HEATER RED |
| 10A. FUSE - WHITE |
| HEATER RED | 120V A.C. |
|
10A. FUSE - WHITE |
|
| 208 or | 10A. FUSE - WHITE | 208 or | |
|
|
| 240V A.C. |
| 240V A.C. | |
10A. FUSE - BLACK | 120V A.C. | 10A. FUSE - BLACK |
| 10A. FUSE - BLACK | 120V A.C. |
|
LIMIT SW. - BLACK | Fig. 1 | LIMIT SW. - BLACK | Fig. 2 | LIMIT SW. - BLACK | Fig. 3 |
|
For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194 °F)
1.Unit shipped per Fig. 1, wired for 120V
2.For 208 - 240V
3.For 120/208 - 240V
FIELD WIRING TERMINAL BLOCK DIAGRAM
Models with Master ON/OFF Switch
RED
TO MASTER
ON/OFF120V A.C.
SWITCH
BLACK
Fig. 1
RED |
| |
TO MASTER | 208 or | |
ON/OFF | ||
240V A.C. | ||
SWITCH |
|
BLACK
Fig. 2
RED |
|
|
TO MASTER | 120V A.C. | 208 or |
ON/OFF | 240V A.C. | |
SWITCH | 120V A.C. |
|
BLACK
Fig. 3
For all 208 - 240 Volt Connections: Use No. 10 AWG Wires suitable for 90°C (194°F)
1.Unit shipped per Fig. 1, wired for 120V
2.For 208 - 240V
3.For 120/208 - 240V