ADJUSTMENT & OPTIONAL SETTINGS (cont)
3.To decrease the pump speed, press and hold the
4.Repeat as necessary at the remaining dispense stations.
5.Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.
NOTE: Dispense at least 12 oz. of finished product before dispensing a sample to check brix. This will allow the pump time to adjust to the new speed.
Chilled Water Flow Testing and Adjustment
1.Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing.
2.Place a graduated measuring cup or the large chamber of the empty brixing cup
3.Press and hold the “Chilled Water Switch” Fig 4 or Fig 5, for 5 seconds. Note that the beeper sounds once per second (6 times, total) during this period.
4.At the end of the 5 second period, the chilled water will dispense for 3 seconds.
5.Measure the water dispensed. (Approx. 4.5 fl. oz. [133 ml])
6.If adjustment is required, remove all concentrate bottles from dispenser and disconnect any optional ambient concentrate hoses. Remove product shelf from dispenser.
7.Adjust the Chilled Water Flow Valve Fig 8, clockwise to decrease flow rate; counterclockwise to increase flow rate.
8.Repeat steps 3 through 6 as necessary until the desired water flow rate is achieved.
9.Exit the “Pump Speed Programming” mode by simultaneously
pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.
Cup Size Programming (Portion Control Dispensers Only)
1.Enter the “Cup Size Programming” mode by simultaneously pressing the “LARGE” and “SMALL” cup size switches at any dispense station. Note that the beeper sounds twice and that the “PROGRAM” indicator lights steadily.
2.Press and hold the desired cup size switch at the appropriate dispense position until the correct cup volume is achieved. Top up as necessary by momentarily pressing the same cup size switch. Note that if DIP switch #2 on the control board is set to the “on” position, concentrate must be present in order to dispense or program cup sizes.
3.Repeat as necessary for the remaining cup sizes and dispense stations.
4.Exit the “Cup Size Programming” mode by pressing any of the “+/STOP Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.
Dispenser Lockout
Dispense and Rinse functions of the dispenser can be electronically
Mode #1 locks out all dispense functions.
Mode #2 locks out all dispense functions except the chilled water dispense.
15 | 38218.1 030306 |
|