TROUBLESHOOTING (cont.)
PROBLEM
Dispense station not working "refill" LED and beep code.
A)
B)
Refill LED not extinguishing
All stations dispense concentrate only
PROBABLE CAUSE
1.Bottle adapter switch mem- brane
A)Dispense/Rinse switch mem- brane shorted out simultaneously.
B)Dispense/Rinse switch mem- brane open simultaneously.
2.Concentrate lockout (Dipswitch #2) feature activated - locks out station when refill light is ON.
3.Dispense touchpad.
Bottle adapter refill
Main water supply
Internal ON/OFF water valve
Frozen bath
REMEDY
Check for moisture at
Check knob for
Check for proper orientation of the Dispense/Rinse membrane switch.
Hint: Good bottle adapter switch membrane will sound the beeper when you rotate the knob between dispense and rinse to indicate closed position.
Refill product or turn OFF concen- trate lockout feature (Dipswitch #2)
See Schematics and check corre- sponding dispense station button for continuity - replace touchpad.
Check wire terminals going to the probes for proper connection or refill probes need to be cleaned and rinsed.
NOTE: Door switch resets the "Refill" LEDs.
Check for ON position.
Check for ON position.
A)Compressor relay/contacts shorted - replace relay.
B)Recirculating pump - replace or check for kinked flex line.