TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Refrigeration

1. Compressor ON/OFF switch.

Check for "ON" position or no con-

All dispense stations not working

 

tinuity - replace switch.

or all water & refill LED's flash and

 

 

beep 3 times.

2. Dirty condenser filter or fins.

Clean or replace condenser filter.

Note: Cooling failure or excessive

 

 

bath and cabinet temperatures for

3. Condenser fan not running.

Replace fan motor or check fan

m ore than 4 hours will result in

 

blades for obstructions.

touchpad lockout or no dispense.

4. Compressor relay not activat-

Check compressor relay coil for

 

 

ing.

120vac.

 

 

NOTE: Always check power with

 

 

coil attached. If no 120vac - replace

 

 

board. If yes, 120vac - replace

 

 

relay.

 

 

Note: Relay contacts normally

 

 

open.

 

5. Compressor not running.

Check compressor thermal overload

 

 

(N/C). If open check for dirty con-

 

 

denser filter or adequate ventilation

 

 

and space around machine.

 

6. Compressor running and not

Check refrigeration system for leaks

 

cooling.

and proper charge.

Dispenser Locked Out

 

 

All dispense stations not working

1. Dispenser lockout password

See page 17 for instruction on how

or all water & refill LED's flash and

set.

to reset or change password.

beep 3 times.

 

 

Hint: Display light goes out during

 

 

dispenser lockout feature, if the unit

 

 

has lighted graphics.

 

 

Cooling system failure or DBC fault 3.

1.Refrigeration or cold water recir- culation system.

Check all previous items that pre- tain to refrigeration or cold water recirculation