TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

REMEDY

Unit is not working and no beep/light

1. Step-down transformer.

Check for 120/24 vac. If no 24vac

fault codes

 

reading, replace step-down trans-

 

 

former.

 

2. Main control board.

If 24 vac present and no red LED,

 

 

replace control board..

 

 

Hint: Red LED on main control board

 

 

is powered from the step-down

 

 

transformer 24 vac and rectified to

 

 

24 vdc by the rectifier.

Difficulty brixing and/or weak bev-

1. Product viscosity or too cold.

Thorough thaw of product before

erage

 

use (35° - 40°)

 

2. Low water pressure.

Maintain 20 psi or higher and a

 

 

minimum flow rate of 3 fl oz/sec.

 

3. High water pressure.

Over 100 psi, install a pressure

 

 

regulator and set to 50 psi.

 

4. Dispense valve adjustment set-

A) Perform 3 second water dispense

 

ting.

test. Factory setting is 1.0 oz/sec.

 

 

Acceptable water flow rate is .-0.8

 

 

to 1.5 oz/sec depending on the mix

 

 

ratio (4+1).

 

 

B) Adjust water to proper mix ratio.

 

 

Once water is set, adjust motor

 

 

speed (RPM) to achieve brix %.

 

5. Brix ratio.

Check for proper brix ratio per prod-

 

 

uct using Total Dispense method

 

 

and or refractometer method.

26

38218.1 030306

 

Page 26
Image 26
Bunn S/N 0005473 & UP manual TROUBLESHOOTING cont, Problem, Probable Cause, Remedy, Step-down transformer