ADJUSTMENT & OPTIONAL SETTINGS (cont)

1.Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing.

2.Enter a “Lockout” password as follows:

a)Press and hold the left hand “Hidden Switch” (half filled circle) for mode #1, the right hand “Hidden Switch” (filled circle) for mode #2.

b)In a 5 second period, press and release the “Chilled Water Switch” the number of times that you want the password set to (maximum of 10.) For example: If you want the password set to 3, press and release the “Chilled Water Switch” 3 times in the 5 second period.

c)Release the “Hidden Switch”.

d)At the end of the 5 second period, the password will be confirmed by the “REFILL” indicators flashing the password, and the appropriate lock-out mode will be selected.

3.Exit the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches”. Note that the beeper sounds twice and that the “PROGRAM” indicator extinguishes.

4.To lockout the dispenser, proceed as follows:

a)Press and hold either “Hidden Switch”.

Note: The lock-out mode selected during password programming is automatically selected, regardless of the hidden switch used to lock-out the dispenser.

b)In a 5 second period, press and release the “Chilled Water Switch” the “password” number of times. For example: If the password is set to 3, press and release the “Chilled Water Switch” 3 times in the 5 second period.

c)Release the “Hidden Switch”.

d)At the end of the 5 second period, the dispenser will extinguish the merchandising lamp, and all dispense functions will be disabled.

5.To enable the dispenser, proceed as follows:

a)Press and hold either “Hidden Switch”.

b)In a 5 second period, press and release the “Chilled Water Switch” the “password” number of times. For example: If the password is set to 3, press and release the “Chilled Water Switch” 3 times in the 5 second period.

c)Release the “Hidden Switch”.

d)At the end of the 5 second period, the dispenser will light the merchandising lamp, and dispense func- tions will be enabled.

6.If the password is forgotten, it can be reset to “0” (dispenser lockout disabled) as follows:

Note: The following procedure also clears the programming and service lockout password.

a)Disconnect the dispenser from its power source.

b)Place the “Refrigeration Switch” Fig 2, in the OFF (reward) position.

c)While pressing and holding the “Chilled Water Switch”, connect the dispenser to its power source.

d)Continue to hold the “Chilled Water Switch” until the dispenser beeps three times, then release.

e)The passwords are now returned to “0” (no programming or service lockout password/dispenser lockout disabled.)

f)After 3 minutes, place the “Refrigeration Switch” in the ON (forward) position.

Service Lockout

Should a dispense station become inoperative and require service, the station’s dispense and rinse functions can be independently locked out, while keeping the remaining stations running.

1.To place a single dispense station in “Service Lockout,” open the dispenser door, press and hold either “Hid- den Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds.

2.At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be disabled. Place the DISPENSE/RINSE Knob to “DISPINSE” and close the dispenser door.

3.To remove a dispense station from “Service Lockout,” open the dispenser door, press and hold either “Hid- den Switch” and the desired dispense station “Product Dispense” (“+/Stop”) switch for 10 seconds.

4.At the end of the 10 second period, the beeper will sound a double tone and the dispense position will be enabled. Close the dispenser door.

16

38218.1 030306

 

Page 16
Image 16
Bunn S/N 0005473 & UP manual Service Lockout, ADJUSTMENT & OPTIONAL SETTINGS cont