DIAGNOSTICS
Intermittent flashing of the READY indicator indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault.
FLASHES | CAUSE | THINGS TO CHECK |
|
|
|
1 | Dry Plug - In Fault - | Water Pressure (Is water shut off?) |
| Sheath of temperature probe dry for 10 minutes after | Temperature probe wiring |
|
| Fill valve wiring, function, & strainer |
|
| Green wire between tank and circuit board |
|
|
|
2 | Low Tank Level Fault - | Water pressure (Is water shut off?) |
| Level probe dry for 7 minutes after fill valve is energized | Shorting pin on J6 connector of control board |
|
| not on correct set of pins (See page 7) |
|
| Level probe wiring |
|
| Temperature probe wiring |
|
| Fill valve wiring, function, & strainer |
|
|
|
3 | Low Water Temperature Fault - | Tank heater wiring & function |
| Sensor in tank is calling for heat for 30 minutes or more | Temperature probe wiring |
|
|
|
4 | Tank Sensor Disagreement - | Temperature probe wiring |
| Level probe detects water, but dry | Level probe wiring |
|
| Green wire between tank and circuit board |
|
|
|
5 | Temp Sensor | Sensor not connected to circuit board |
|
|
|
6 | Temp Sensor | Sensor wires shorted together or to chassis |
|
|
|
Page 14 | 29466 | 061599 |
|
|