SERVICE (cont.) |
|
| |
BREW SOLENOID VALVE (HOT COFFEE) | 6. | Check the hot coffee solenoid valve for coil ac- | |
|
|
| tion. Connect the brewer to the power source. With |
|
|
| TEA/OFF/COFFEE switch in the "COFFEE" position |
|
|
| press the start switch and listen carefully in the |
|
|
| vicinity of the solenoid valve for a "clicking" sound |
|
|
| as the coil magnet attracts. |
|
| 7. | Disconnect the brewer from the power source. |
|
| If the sound is heard as described and water will not | |
|
| pass through the solenoid valve, there may be a block- | |
|
| age in the water line before the solenoid valve or, the | |
|
| solenoid valve may require inspection for wear, and | |
|
| removal of waterborne particles. | |
|
| If the sound is not heard as described, replace the | |
|
| solenoid valve. | |
|
| Removal and Replacement: | |
| P1960.60 | 1. | Remove all wires from solenoid valves. |
| 2. | Turn off the water supply to the brewer. | |
| FIG. 2 HOT COFFEE BREW SOLENOID VALVE | ||
| 3. | Disconnect the water lines to and from the sole- | |
|
| ||
Location: |
| noid valves. | |
| Viewing the brewer from the rear the hot coffee | 4. | Remove the two |
brew solenoid valve is mounted on the left side of the |
| mounting bracket to the brewer base. | |
mounting bracket. | 5. | Lift out the bracket. | |
|
| 6. | Remove the two |
Test Procedures: |
| ing the hot coffee solenoid valve to the mounting | |
1. Disconnect the brewer from the power source. |
| bracket. | |
2. Disconnect the white/red and white wires from the | 7. | Securely install the new hot coffee solenoid valve | |
| hot coffee solenoid valve. With the TEA/OFF/COF- |
| to the mounting bracket. |
| FEE switch in the "COFFEE" position press the start | 8. | Attach the mounting bracket to the brewer base. |
| switch. | 9. | Securely fasten the water lines to and from the |
3. | With a voltmeter, check the voltage across the |
| solenoid valves. |
| white/red and white wires. Connect the brewer to | 10. | Refer to Fig. 3 when reconnecting the wires. |
| the power source. The indication must be 120 volts |
|
|
| ac. |
|
|
4. Disconnect the brewer from the power source. |
| WHI to Main | |
|
|
| |
|
|
| Harness |
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to Wiring
Diagram and check brewer wiring harness.
5. Check for continuity across the hot coffee sole- | WHI/RED |
|
| |
to Switch HOT COFFEE |
|
| ||
noid valve coil terminals. | BREW SOLENOID |
|
| |
|
|
| ||
If continuity is present as described, reconnect the | WHI/BLU | ICED TEA BREW |
| |
SOLENOID |
| |||
white/red and white wires to the solenoid. | to Switch |
| ||
SOLENOID |
| |||
|
| DILUTION |
| |
If continuity is not present as described, replace the |
|
| P1364 | |
solenoid valve. | FIG.3 SOLENOID VALVE TERMINALS | |||
| ||||