SERVICE (cont.)
RELAY (or CONTACTOR on Early Models)
Location:
The relay (or contactor) is located inside the dis- penser chassis on the lower outside of the component
If continuity is present as described, disconnect the dispenser from power source and reconnect wires to terminals #6 and #8, the relay is working.
If continuity is not present as described, do the same continuity test across terminals #2 and #4. If continu- ity is present between terminals #2 and #4, reconnecr wires to terminals #2 and #4 instead of #6 and #8.
If continuity is not present as described, replace the relay.
Removal and Replacement:
1.Disconnect the wires from the relay.
2.Remove the two
3.Install the new relay on the chassis using two
4.Refer to Fig. 33 and 34 to reconnect the wires.
Early Model
bracket.
Test Procedures:
1. | Disconnect the dispenser from the power source. |
2. | Remove the right side panel. |
3. | Connect the dispenser to the power source. |
4. | Turn on power (I/O) switch. Verify UPPER case |
| “ICE” or “CHILL” mode. |
5. | With a voltmeter, check the voltage across the white |
Terminal #4
Terminal #2
Terminal #6
BLK from Main
Harness/Power Cord
Terminal #8
WHI/ORN from
Compressor Harness
Terminal #0
WHI from Main Harness
Terminal #1
ORN from
Control Board
wire and the orange wire. |
The indication must be: |
a) 120 volts ac for 120 volt models. |
b) 230 volts ac for 230 volt models. |
6. Disconnect the dispenser from the power source. |
If voltage is present as described, proceed to #7.
If voltage is not present as described, refer to the Wir- ing Diagram and check the dispenser wiring harness. If harness has continuity, replace Control Board.
7.Disconnect the black wire and the WHI/ORN wires from relay terminals #6 and #8.
8.Connect the dispenser to the power source.
9.Turn on power (I/O) switch. Verify UPPER case “ICE” or “CHILL” and check for continuity across terminals on relay.
| P1333 | |
FIG. 33 CONTACTOR TERMINALS | ||
| ||
|
Late Model | ||
Terminal #0 | Terminal #1 | |
WHI from | ORN from | |
Main Harness | Main Harness | |
| Terminal #8 | |
| BLK from | |
| Main Harness | |
Terminal #2 | Terminal #6 | |
Terminal #4 | WHI/ORN from | |
Main Harness | ||
| ||
FIG. 34 RELAY TERMINALS | ||
39 | 41084 102709 | |
|