Bunn ULTRA-2 DEFROST MINUTES - OFF + FREEZE MINUTES 60 +, PM COMPLETE ? NO YES 6 MONTH PM ON +

Models: ULTRA-2

1 23
Download 23 pages 57.86 Kb
Page 13
Image 13
DEFROST MINUTES (-) OFF (+)

This feature allows the machine to defrost the product during day time operation. The defrost minutes setting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost periods. These modes when activated will function anytime the machine is in day mode operation. The machine will automatically stay in the freeze mode for 2 hours after waking up from the night time mode. (This feature was not offered on some early models).

DEFROST MINUTES (-) OFF (+)

FREEZE MINUTES

(-) 60 (+)

Preventive Maintenance Complete?

This function is used to reset a reminder message Preventive Maintenance Due every six months. The ma- chine will not shut down if service is not performed. When the service is performed and the message is answered YES (ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing (-) ULTRA hidden switch. (Some early models displayed the word “ENABLED” in place of the word “ON”).

PM COMPLETE ?

NO YES

6 MONTH PM

(-) ON (+)

13

32080 022003

 

Page 13
Image 13
Bunn ULTRA-2 manual DEFROST MINUTES - OFF + FREEZE MINUTES 60 +, PM COMPLETE ? NO YES 6 MONTH PM ON +