Bunn ULTRA-2 manual User Notices, Site Preparation, Electrical Requirements

Models: ULTRA-2

1 23
Download 23 pages 57.86 Kb
Page 3
Image 3
USER NOTICES

USER NOTICES

Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.

27442.0000

!WARNING

DO NOT OVERLOAD CIRCUIT.￿

ALWAYS ELECTRICALLY GROUND THE CHASSIS￿ OR ADAPTOR PLUG.￿

DO NOT DEFORM PLUG OR CORD.￿

FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES.￿ KEEP COMBUSTIBLES AWAY.

FAILURE TO COMPLY RISKS EQUIPMENT￿ DAMAGE, FIRE OR SHOCK HAZARD.

READ THE ENTIRE OPERATING MANUAL￿ BEFORE USING THIS PRODUCT

00986.0002E 5/98 ©1994 Bunn-O-Matic Corporation

00986.0002

CHARGE

Type R404A, Amount 10 oz

Design Pressures: High 240 Low 34

32162.0000 (ULTRA-2)

CHARGE

Type R404A, Amount 9.5 oz(269g)

Design Pressures: High 215 Low 40

29373.0000 (ULTRA-2A)

Risk of Electric Shock.

This equipment may have two power supply cords. Unplug all cords before moving or servicing this equipment.

29947.0000

SITE PREPARATION

The dispenser is very heavy. Place it on a sturdy counter or shelf capable of supporting at least 180 lbs. It is for indoor use only.

The dispenser must have at least six inches of space behind it. This space is needed for airflow, air filter removal, and cleaning. A clearance of at approximately six inches is recommended between the dispenser sides and the wall or another appliance. The dispenser performs better if not placed near any heating appliance. Leave some space so the dispenser can be moved for cleaning.

ELECTRICAL REQUIREMENTS

CAUTION – Improper electrical installation will damage components. An electrician must provide electrical service as specified below.

Model ULTRA-2, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 120 volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.

(Refer to the dataplate for exact electrical requirements.)

Model ULTRA-2A, This dispenser has an attached cordset and requires a 2-wire, grounded, individual branch circuit rated 230 volts ac, 10 amp, single phase, 50 Hz. (Refer to the dataplate for exact electrical requirements.)

NOTE – Bunn-O-Matic does not recommend the use of any extension cord with these dispensers.