DAY TO CLEAN OFF

Day To Clean Off (formerly Days....Disabled)

This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is 0 or DISABLED. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if “Clean Lockout” is activated. To reset the Clean Due Today message or lockout, two functions must be per- formed. Either power off the dispenser using the I/O (ON/OFF) switch and allow the barrels or cooling drums to warm over 50°F, or scroll to the Cleaning Guide and perform the cleaning service. The barrels will warm to over 50°F when cleaned with warm water and the message will disappear.

DAY TO CLEAN OFF

DAYS TO CLEAN 14

(-) NEXT (+)

(-) NEXT (+)

CLN MESSAGE ONLY

CLEAN LOCKOUT

(-) NEXT (+)

(-) NEXT (+)

Consistency Adjust Lock

This is an option of locking the Set Consistency function by selecting + (YES) or - (NO).

YES THICK ADJUST

NO THICK ADJUST

(-) NEXT (+)

(-) NEXT (+)

 

 