Coffee Weight/Timer Settings
Approx. 4.0 seconds per ounce, Medium Roast, Drip Grind.
Approx. 5.5 seconds per ounce, Dark Roast, Drip Grind.
Time will vary depending on bean density & grind size.
Check samples by weight.
DIGITAL CONTROL DISPLAY ASSEMBLY FUNCTION LIST -
FUNCTION NO. | FUNCTION |
Place funnel with filter into rails, press (Func) button to advance to Function One.
1.When entering this function, load sensor is tared. To gain access to remaining functions, press (+) or
(0)now press (Func).
2.Set weight offset, right grinder. Press (+) or
3.Set weight offset, left grinder. Press (+) or
4.Enter calibration mode? If yes, press (+) display will read (1) then press (Func). If no, press (Func).
NOTE - Pressing (Func) will return to idle display.
5.Use present weight as tare for calibration? If yes, press (+). Display will read
(1)then press (Func). If no, press (Func).
6.To calibrate by grinding coffee, press (+) display will then read (1) then press (Func).
7.Enter desired calibration weight using (+) and
8.Weigh sample grind and enter actual weight onto the display by pressing (+) or
10.Enter new password. To keep same password press (Func), to change pass- word press (+) or
NOTE: Display shows
NOTE: WDG2 Models can be converted from weight based settings to timed settings by pressing the (+) and
RANGE
MIN. MAX.
0000 9999
0.009.99
0.009.99
0 = No 1 = Yes
0 = No 1 = Yes
1 = Grind
3.0016.00
0.0016.00
0000 9999
10 | 10854 030300 |
|