Cabletron Systems 9T122-08 Exiting the Token Ring Port Configuration Screen, And if the port is

Models: 9T122-08

1 36
Download 36 pages 50.61 Kb
Page 22
Image 22
Table 4. Token Ring Port Operational Codes

9T122-08 Module Specific Information

Table 4. Token Ring Port Operational Codes

 

And if the port is

 

If the port is a...

administratively

Then, the operational status is:

 

turned...

 

 

 

 

 

 

 

Ring Port

 

ACT (Active)

RI (ring-in) or

 

The port is on and is passing data to the ring.

RO (ring-out)

ON

WRP (Wrapped)

 

 

 

 

The port is on, but it is autowrapped, either because of a

 

 

cable failure or because the cable is not connected.

 

 

 

 

OFF

DIS (Disabled)

 

 

The port is off (wrapped by Management).

 

 

 

Lobe Port

 

INS (Inserted - phantom link is detected)

 

ON

The lobe port is inserted into the ring.

 

ENB (Enabled - no phantom link is present)

 

 

 

 

The lobe port is not inserted into the ring.

 

 

 

 

 

LNK (Linked - phantom link is detected)

 

 

The lobe port is trying to gain access to the ring, but it has

 

OFF

been prevented.

 

 

BYP (Bypassed -no phantom link is present)

 

 

The lobe port is not attempting to gain access to the ring.

 

 

 

 

 

FLT (Speed Fault)

 

ON or OFF

The ring speed of the port is in conßict with the ring speed

 

 

of the designated token ring. The port will remain

 

 

wrapped.

 

 

 

Exiting the Token Ring Port Configuration Screen

To exit the Token Ring Port ConÞguration Screen, use the arrow keys to highlight RETURN, then press the Return key.

20

Page 22
Image 22
Cabletron Systems appendix Exiting the Token Ring Port Configuration Screen, 9T122-08 Module Specific Information, turned