20 Installation ELS100-24TXG
10Base-T/100Base-TX Ports
The 10Base-T/100Base-TX ports use RJ-45 connectors. Figure 2-5
shows an RJ-45 connector being inserted into a port.
Figure 2-5. Inserting an RJ-45 Connector into a Port
The 10Base-T/100B ase-TX ports inter face to UTP cabl ing for connection
to 10Base-T or 100Base-TX network segments or end-stations. These
UTP connections meet the requirements of ISO 8877, specified by
10Base-T, Section 14 of the IEEE 802.3 specifi cation. The por ts are wired
with the MDI-X function implemented. Workstations or servers can be
connected to the ELS100-24TXG swi tch using standard straight-through
wired cables.
For connections to hubs or other switches, a crossover cable may be
necessary (refer to the “MDI/MDI-X Crossover Cable Wiring” section in
Appendix A). See Table A-2 for 10Base-T/100Base-TX connector pin
assignments.