TESTING AND LANVIEW
ON LINE LED
When this green LED is lit, the bridge is on line and operational. The unit has completed a self diagnostics test and is capable of forwarding packets.
STAND BY LED
When this yellow LED is lit, the bridge is in the “Stand by” mode and not capable of forwarding packets.
NOTE: There are separate XMT, RCV, CP, and POK LEDs for each port on the NB20E and NB25E.
TRANSMIT (XMT) LED
When this green LED is flashing, the bridge is transmitting packets to that network segment.
RECEIVE (RCV) LED
When this yellow LED is flashing, bridge is receiving a data packet from that segment.
COLLISION PRESENT (CP) LED
When this red LED is flashing, a collision is occurring on that segment.
PORT OK (POK) LED
This green LED is lit to indicate that the transceiver is connected, and that the port has passed an internal Loop Back Test and is ready for transmission.
4.3USING THE FORWARD BROADCAST SWITCH
The Forward Broadcast switch, Figure