High Elevation Installation
Your fireplace or fire pit is approved for elevations up to 4500 feet in the US and Canada.
When installing this appliance at an elevation above 4500 feet in the US, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce the input by 4% for each 1,000 feet above sea level, unless the heating value of the gas has been reduced, in which case this general rule will not apply. To identify the proper orifice size, check with your local gas utility.
When installing this unit at an elevation above 4,500 feet in Canada check with your local authorities. Consult the local gas utility for assis- tance in determining the proper orifice for your location.
Natural Gas Conversion
For Both Fireplaces or Fire Pits
CAUTION: This service is to be completed only by an authorized gas appliance installer. Do not attempt this conversion on your own as there is risk of serious injury or death.
To The Authorized Gas Appliance Installer:
All Cal Flame fireplaces and firepits are shipped from the factory equipped to burn on liquid propane fuel. Enclosed with this kit is a natural gas conversion kit for converting this unit to natural gas. To perform this conversion, follow the directions below and to the local regulation standards in your area.
1.Make sure unit is not in operation and is cool enough to perform this service. Shut off and disconnect propane fuel source at the regulator end.
2.Carefully remove the storage cover, lava rocks and fire logs. Turn unit over to access hose connections underneath.
3.While holding the propane orifice in place with a wrench, unscrew brass fitting on fuel inlet hose. Unscrew propane orifice and re- move.
4.Using the new brass natural gas orifice
2009 Fireplaces and Firepits
17
Installation / Assembly
LTR20091006, Rev. B | www.calspas.com |