6. Remove the nailer from

 

Adjusting the Nail Penetration

(Continued)

 

 

the work surface. The

 

 

The tool is equipped with an adjustable

Operational Mode - Single Cycle

Work Contact Element

 

 

depth of drive feature. This allows the

(WCE) must return

 

 

 

Always know the

 

 

user to determine how deep a fastener

 

to its original down

 

 

 

operational mode of

 

 

will be driven into the work surface.

 

position. The nailer must not

 

the tool before using. Failure to know

 

1. Adjust operating pressure so nails

the operational mode could result in

operate. Do not use the tool if it

are driven consistently. Do not

death or serious personal injury.

 

operates while lifted from the work

 

 

 

 

exceed 110 psi.

 

This tool requires the

 

 

surface. Personal injury may result.

 

 

 

2. To drive the nail shallower, turn

trigger to be pulled

 

 

7. Pull the trigger and depress the

 

each time a nail is

 

 

 

the wheel (C) to right to the extent

 

 

work contact

 

 

driven. The nailer

1

2

 

 

desired.

 

element (WCE)

 

 

 

can be actuated by

 

 

 

 

 

 

 

 

against the work

 

 

 

 

depressing the WCE against the work

1

2

 

 

surface. The nailer

 

 

surface followed by pulling the trigger.

 

 

 

 

MUST NOT operate.

 

 

 

 

 

 

 

 

 

 

 

 

The trigger must be released to reset

8. Depress the Work Contact Element

 

 

the tool before another nail can be

 

 

 

 

(WCE) against

 

 

(C)

 

driven.

 

 

 

 

 

 

 

the work surface.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Work contact element (WCE)

Pull the trigger.

1

2

 

 

The nailer MUST

 

 

 

Check the operation

 

 

 

 

 

operate.

 

 

 

 

 

of the Work Contact

 

 

3. To sink a nail deeper, turn the wheel

 

 

 

 

Element (WCE) trip mechanism before

An improperly

 

 

(C) to left to the extent desired.

each use. The WCE must move freely

functioning tool

 

 

without binding through its entire

 

must not be used. Do not actuate the

4. Make sure trigger and

 

travel distance. The WCE spring must

tool unless the tool is placed firmly

work contact element

 

return the WCE to its fully extended

against the work piece.

 

 

(WCE) move freely up

 

position after being depressed. Do

 

 

 

 

 

 

Loading/Unloading The Nailer

and down without

 

not operate the nailer if the WCE trip

 

mechanism is not operating properly.

1. Always disconnect the tool from the

binding or sticking after

Personal injury may occur.

 

 

each adjustment.

 

 

 

air supply before loading fasteners.

 

1.

Disconnect the air

 

 

 

 

 

 

2. Insert nails into rear slot as shown.

Adjusting The Direction Of The

 

supply from the

 

 

 

 

 

3. Pull pusher back until it is behind

Exhaust

 

 

nailer.

 

 

The tool is equipped

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with an adjustable

 

2.

Remove all nails

 

 

 

 

 

direction exhaust

 

 

from the magazine

 

 

 

 

 

deflector. This is

 

 

(see Loading/

 

 

 

 

 

intended to allow

Rotate

 

Unloading).

 

 

 

 

 

the user to change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the direction of the exhaust. Simply

3. Make sure the trigger

 

 

 

 

 

twist the deflector to any direction

 

and work contact

 

 

 

 

 

desired.

 

 

element (WCE) move

 

 

nail clip, then release.

 

 

 

 

 

freely up and down

 

 

4. Always unload all fasteners before

 

 

 

without sticking or

 

 

 

 

 

 

 

removing tool from service.

 

 

 

 

binding.

 

 

 

 

 

 

 

 

Unloading is the reverse of loading,

 

 

 

 

 

 

 

 

4.

Reconnect air

 

 

except always disconnect the air

 

 

 

supply to the

 

 

hose before unloading.

 

 

 

 

 

nailer.

 

 

 

 

 

 

 

5.

Depress the Work

 

 

 

 

 

 

 

 

Contact Element

 

 

 

 

 

 

 

 

(WCE) against the

 

 

 

 

 

 

 

 

work surface without

 

 

 

 

 

 

 

 

pulling the trigger.

 

 

 

 

 

 

 

 

The nailer must not operate.

 

 

 

 

 

 

Do not use the tool if it operates

 

 

 

 

 

 

without pulling the trigger. Personal

 

 

 

 

 

 

injury may result.

 

 

 

 

 

 

 

5