Oilless Compressors

FP2048, FP2049

General Safety Information (Continued)

3.Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.

4.Keep visitors away and NEVER allow children in the work area.

5.Wear safety glasses

and use hearing protection when operating the pump or unit.

!DANGER

Never attempt to repair or modify a tank! Welding, drilling or any

other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn or damaged tanks.

Drain liquid from

! WARNING tank daily.

13. Tanks rust from moisture build-up,

which weakens the tank. Make sure

to drain tank daily and inspect

Installation

LOCATION

It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.

A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.

Do not locate the

! CAUTION compressor air inlet near steam, paint spray, sandblast

Para Ordenar Repuestos Sírvase Llamar al Distribuidor Mas Cercano A Su Domicilio

Sírvase darnos la siguiente información:

Puede escribirnos a:

-Número del modelo

Campbell Hausfeld / Attn: Parts Department

-Número de Serie (de haberlo)

100 Production Drive

-Descripción y número del repuesto según la lista de repuestos

Harrison, OH 45030 U.S.A.

 

2a

 

7

14

1

16

12

 

6.Do not stand on or use the pump or unit as a handhold.

7.Before each use, inspect compressed air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.

8.Check all fasteners at frequent intervals for proper tightness.

! WARNING

Motors, electrical equipment and controls

can cause electrical arcs

that will ignite a flammable gas or vapor. Never operate or repair in or near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor.

!CAUTION

Compressor parts may

periodically for unsafe conditions

such as rust formation and

corrosion.

14. Fast moving air will stir up dust and

debris which may be harmful. Release

air slowly when draining moisture or

depressurizing the compressor system.

SPRAYING PRECAUTIONS

! WARNING

Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit.

15.Do not smoke when spraying paint, insecticides, or other flammable substances.

16.Use a face mask/

respirator when

areas or any other source of contamination. This debris will damage the motor.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal

120 volt circuit and has a grounding

plug that looks like the plug illustrated

in Fig. 1. Make sure the product is

connected to an outlet having the

same configuration as the plug. This

product must be grounded. In the

event of an electrical short circuit,

grounding reduces risk of electrical

shock by providing an escape wire for

electric current. This product is

equipped with a cord having a

grounding wire with an appropriate

grounding plug. Plug must be plugged

into an outlet that is properly installed

and grounded in accordance with all

 

 

2b

 

 

11

9

 

20

 

 

 

3

15

 

 

 

4

 

6

5

13

2b

19a

19b

18b

18a

10

22

be hot even if the unit is stopped.

spraying and spray in a well ventilated area

local codes and ordinances.

Liste de Repuestos

21

8

FP204800, FP204900

9. Keep fingers away from a running

compressor; fast moving and hot

to prevent health and fire hazards.

17. Do not direct paint or other sprayed

Grounding

Pin

No. de

Numero

 

No. de

Numero

 

Ref. Descripción

de pieza

Ctd.

Ref. Descripción

de pieza

Ctd.

parts will cause injury and/or burns.

10. If the equipment should start to

abnormally vibrate, STOP the

engine/motor and check

immediately for the cause. Vibration

is generally a warning of trouble.

11. To reduce fire hazard, keep

engine/motor exterior free of oil,

solvent, or excessive grease.

Never remove or ! WARNING attempt to adjust

safety valve. Keep safety valve free from paint and other accumulations.

material at the compressor. Locate

compressor as far away from the

spraying area as possible to

minimize overspray accumulation

on the compressor.

18. When spraying or cleaning with

solvents or toxic chemicals, follow

the instructions provided by the

chemical manufacturer.

TEST RESET

Grounded Outlet

Figure 1 - Grounding Method

!DANGER

Improper use of grounding plug can result in a possible risk of electrical shock!

1

Cubierta con mango

FP204822AV

1

2 (a, b)

 

 

 

Ensamblaje del mango

FP204823AV

1

3

Manómetro del tanque

FP204012AV

1

4

Regulador

FP204013AV

1

5

Múltiple

FP204835AV

1

6

Válvula de seguridad

V-215102AV

1

7

Interruptor

FP204824AV

1

8

Llave de drenaje

D-1403

1

9

Ensamblaje de la bomba/motor

FP204825AV

1

10

Presostato

FP204836AV

1

11

Kit de tubo de escape

FP204826AV

1

12

Tornillos de la tapa -

Artículo estándar

 

 

M6-1.0 x 20

de ferretería

4

13

Manguera de 7,6 m (25 pies)

MP302700AV

1

14

Juego de herramientas (5 piezas)FP204008AV

1

15

Válvula de chequeo

FP204827AV

1

16

Cubierta de almacenamiento

FP204828AV

1

17

Juego de etiqueta adhesiva

 

 

 

(no se muestra)

FP204829AV

1

18 (a, b)

 

 

 

Kit de aislador

FP204830AV

1

19 (a, b)

 

 

 

Guarda de bomba/motor

FP204831AV

1

20

Filtro

FP204832AV

1

21

Patas de caucho

FP204833AV

1

22

Cordón eléctrico

FP204834AV

1

www.chpower.com

2

23 Sp

Page 2
Image 2
Campbell Hausfeld Installation, Oilless Compressors FP2048, FP2049, Liste de Repuestos FP204800, FP204900