4.Wearing safety glasses, drain tank of any remaining air pressure by pulling the ring on the safety valve. Use other hand to deflect any fast moving air that may be directed towards your face.

5.Store compressor in a cool, dry place.

Maintenance

Disconnect power source then release all pressure from the system before attempting to install, service, relocate or

perform any maintenance. Service should be performed by an authorized service representative.

The compressor should be checked often for any visible problems and the

following maintenance procedures should be performed each time the compressor is used.

ASME Safety Valve

Do not remove or attempt to adjust the safety valve!

Check the safety valve by performing the following steps:

1.Plug the compressor in and run until shut off pressure is reached (see Operating Procedure).

2.Wearing safety glasses, pull the ring on the safety valve to release pressure from compressor tank. Use your other hand to deflect fast-moving air from being directed toward your face.

3.The safety valve should automatically close at approximately 40-50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced.

Drain Tank

1.Turn compressor off at foot pedal switch.

2.Check air pressure in tank. To properly drain tank of condensation, tank pressure should be between 20-60 psi. Drain system will not work if there is no pressure in the tank. If tank pressure is above 60 psi, decrease pressure in tank by pulling the ring on the safety valve. Burst of air will be audible.

3.Slowly turn easy drain knob, located below the tank gauge, to the left (counterclockwise) until fluid begins to fill drain cup. Watch draining to make sure drain cup does not overflow. If there is a lot of fluid in the tank, you may need to close drain knob by turning fully to the right (clockwise) then remove the drain cup to dispose of fluid.

4.When fluid stops draining, close drain knob by turning all the way to the right (clockwise).

5.Lift cup up and pull out to dispose of drained fluid. Reinsert cup, making sure to secure in place.

Cleaning

Turn power OFF and clean dust and dirt from motor, tank, and air lines.

Figure 18 - Safety valve

Tank Pressure

Gauge

Easy-Drain Knob

Fill Line

Easy-Drain Cup

Figure 19 - Draining tank