Operation (Continued)

ASME Safety Valve

Do not remove or attempt to adjust the safety valve!

This valve should be checked under pressure occasionally by pulling the ring by hand (See Figure 13). If air leaks after ring has been released, or valve is stuck and cannot be actuated by ring, it MUST be replaced.

Click-To-Set Regulator Knob

uThis knob controls air pressure to an air operated tool, or paint spray gun.

uTurning knob clockwise increases air pressure at outlet.

uTurning counterclockwise will lower air pressure at outlet.

uFully counterclockwise will shut off flow of air completely.

This regulator knob is designed to rotate approximately 270 degrees for all feature settings. If the knob is rotated past minimum operation setting (counterclockwise), the knob will no longer “click” as designed to indicate that the regulator has been placed in a specific setting. The outlet pressure will read zero (0 psi) once the knob is at the minimum operation setting. Continuous turning of the regulator knob past minimum operation setting (counterclockwise) could result in the regulator knob coming loose and detaching.

If outlet pressure gauge is at zero (0) psi, DO NOT turn knob counterclockwise.

If regulator knob is turned and a “click”

is no longer heard, DO NOT turn knob counter clockwise.

Reassembly

If you do turn the regulator knob too far past minimum operation setting ( counterclockwise) and the knob does come off, use these steps to reassemble the regulator:

1.Align the spring into central position.

2.Locate retaining latch on inside of regulator knob.

3.Align retaining latch to the aluminum threads of the regulator body.

4.Attach at an angle, catching the retaining latch under the beginning of the aluminum threads.

5.Apply pressure to align knob to regulator body.

6.Turn clockwise until the knob clicks.

For further assistance or questions, please call 1-800-543-6400.

Outlet (Tool) Pressure Gauge

1.This gauge shows at-a-glance, air pressure at outlet. Air pressure is measured in pounds per square inch (psi).

2.Be sure this gauge reads ZERO before changing air tools or disconnecting hose from outlet.

Tank Pressure Gauge

Gauge shows pressure in tank indicating compressor is building pressure properly.

Storage Top

The storage tray compartments, located on the top of the compressor, are designed for easy tool storage. Unique tool kits, available at your local retailer or on www.chpower.com, store easily on top of the unit.