Campbell Hausfeld IN629500AV, WL6700 Series Troubleshooting Guide, Symptom Cause Solution

Models: WL6700 Series IN629500AV

1 68
Download 68 pages 39.81 Kb
Page 18
Image 18

Operating Instructions and Parts Manual

Troubleshooting Guide

Symptom

cause

solution

Compressor will not run

1.

No electrical power

1.

Plugged in? Switch on? Check fuse/breaker

 

2.

Breaker open

2.

Reset, determine cause of problem

 

3.

Pressure switch bad

3.

Replace

 

4.

Motor over worked

4.

Turn off, let cool, turn on.

 

5.

Tank pressure above cut-in

5.

Bleed tank pressure down to cut-in.

 

 

 

 

 

 

 

Fuses blow/circuit breaker

1.

Incorrect size fuse, circuit overloaded

1.

Check for proper fuse, use time-delay fuse.

trips repeatedly

 

 

 

 

Disconnect other electrical appliances from circuit

 

 

 

 

 

or operate compressor on its own branch circuit

 

2.

Worn check valve

2.

Replace

 

 

 

 

 

 

Do not disassemble check valve with

 

 

 

 

 

 

 

 

 

 

 

 

air in tank; bleed tank

 

 

 

 

 

 

Tank pressure drops when

1. Loose connections (fittings, tubing,

compressor shuts off

etc.)

1.Check all connections with soap and water solution. Tighten; or remove and apply pipe dope or pipe tape to the threads, then reassemble.

 

2.

Open tank drain

2.

Close drain

 

 

 

 

 

Air output lower than

1.

Air leaks in piping (on machine or in

1.

Check all connections with soap and water

normal/low discharge

 

outside system)

 

solution. Tighten; or remove and apply pipe dope

pressure

 

 

 

or pipe tape to the threads, then reassemble.

 

2.

Piston ring worn

2.

Replace

 

3.

Excessive air usage

3.

Decrease air usage; compressor not large enough

 

 

 

 

for air requirement

 

4.

Open tank drain

4.

Close tank drain

 

 

 

 

 

Excessive moisture in

1.

Excessive water in tank

1.

Drain tank

discharge air

 

 

 

 

 

2.

High humidity

2.

Move to area of less humidity; use air line filter

 

 

 

 

 

Compressor runs

1.

Defective pressure switch

1.

Replace switch

continuously

 

 

 

 

 

2.

Excessive air usage

2.

Decrease air usage; compressor not large enough

 

 

 

 

for air requirement

 

 

 

Motor runs but no air output

Belt worn

Replace belt

 

 

 

 

 

18www.chpower.com

Page 18
Image 18
Campbell Hausfeld IN629500AV, WL6700 Series operating instructions Troubleshooting Guide, Symptom Cause Solution