NB356502
Fasteners Information
Nails used in the Campbell Hausfeld NB356502 Angle Finish Nailer will also work in Sears 18329, Porter Cable DA250, Senco SFN2B, SFN1 and SFN40..
Troubleshooting Chart
Stop using stapler immediately if any of the following problems occur. Serious personal injury could occur. Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
Symptom | Possible Cause(s) | Corrective Action | ||
Air leaking at trigger valve | Replace | |||
area.. | damaged | Contact Element (WCE) | ||
|
|
|
| |
Air leaking between housing | 1. Damaged | 1. | Replace | |
and nose.. | 2. | Damage to bumper | 2. | Replace bumper |
| ||||
|
|
|
|
|
Air leaking between housing | 1. | Loose screws | 1. | Tighten screws |
and cap.. | 2. | Damaged gasket | 2. | Replace gasket |
| ||||
|
|
|
|
|
Nailer skips driving nail | 1. | Worn bumper | 1. | Replace bumper |
| 2. | Dirt in nose piece | 2. | Clean drive channel |
| 3. | Dirt or damage prevent staples or pusher | 3. | Clean magazine |
|
| from moving freely in magazine |
|
|
| 4. | Damaged pusher spring | 4. | Replace spring |
| 5. | Inadequate air flow to stapler | 5. | Check fitting, hose, or compressor |
| 6. | Worn | 6. | Replace and lubricate |
|
| lubrication |
|
|
| 7. | Damaged | 7. | Replace |
| 8. | Air leaks | 8. | Tighten screws and fittings |
| 9. | Cap gasket leaking | 9. | Replace gasket |
|
|
|
|
|
Nailer runs slow or has loss | 1. | Nailer not lubricated sufficiently | 1. | Lubricate nailer |
of power | 2. | Broken spring in cylinder cap | 2. | Replace spring |
| ||||
| 3. | Exhaust port in cap is blocked | 3. | Replace damaged internal parts |
|
|
|
| |
Nails are jammed in nailer | 1. Guide on driver is worn | 1. | Replace guide | |
| 2. | Nails are not correct size | 2. | Use only recommended nails |
| 3. | Nails are bent | 3. | Replace with undamaged nails |
| 4. | Magazine or nose screws are loose | 4. | Tighten screws |
| 5. | Driver is damaged | 5. | Replace driver |
www.chpower.com
7