Air Cleaner / Dryer
Air Cleaner / DryerModel PA208503
Nettoyeur / Sécheur à AirModéle PA208503
Purificador de Aire / SecadorModelo PA208503

For Replacement Parts, Call 1-800-543-6400

Please provide following information:

Address parts correspondence to:

-Model number

Campbell Hausfeld / Attn: Parts Dept.

-Serial number (if any)

100 Production Drive

-Part description and number as shown in parts list

Harrison, OH 45030 U.S.A.

Pour Pièces De Rechange, Appeler 1-800-543-6400

See Warranty on page 3 for important information about commercial use of this product.

Operating Instructions and Parts Manual

Model PA208503

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Air Cleaner / Dryer

S’il vous plaît fournir l’information suivante :

Correspondance :

-Numéro du modèle

Campbell Hausfeld / Attn: Parts Department

-Numéro de série (si applicable)

100 Production Drive

-Description de la pièce et son numéro sur la liste de pièces

Harrison, OH 45030 U.S.A.

Para Ordenar Repuestos, Sírvase Ilamer al Concesionario más Cercano a su Domicilio

Sírvase darnos la siguiente iinformación:

Puede escribirnos a:

-Número del modelo

Campbell Hausfeld / Attn: Parts Department

-Número de Serie (de haberlo)

100 Production Drive

-Descripción y número del repuesto según la lista de repuestos

Harrison, OH 45030 U.S.A.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

3

Figure 2 / Figure 2 / Figura 2

Replacement Parts List

Liste de Pièces de Rechange

Lista de Repuestos

Ref. No.

 

 

 

Part Number

Qty.

No. Ref.

 

 

 

Numero de Piéce

Qte.

No. de Ref.

Description

Description

Descripción

Número del repuesto

Ctd.

1

Modular

Fixation

Ménsula

SX139600AV

1

 

bracket

modulaire

modular

 

 

2

Replacement

Siccatif de

Desecante de

PA2086

1

 

desiccant

rechange

repuesto

 

 

 

(Not shown)

(Pas indiqué)

(No se muestra)

 

 

3

Coalescing Filter

Cartouche filtrante

Elemento del

PA208703AV

1

 

Element

combinaison

filtro de fusión

 

 

 

 

 

 

 

 

www.chpower.com

 

 

 

 

 

Description

The Campbell Hausfeld Air Cleaner / Dryer is designed to remove dirt, most contaminants, oil vapors and water from compressed air. It is a two part system consisting of a coalescing filter which removes most contaminants, oil vapors and condensed water and a desiccant dryer which removes water vapor.

Unpacking

After unpacking the air cleaner / dryer, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates

an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Warning

indicates

a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution indicates

a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.

Notice indicates

important information, that if not followed, may cause damage to equipment.

General Safety

Information

CALIFORNIA PROPOSITION 65

You can create dust when you cut, sand, drill or grind

materials such as wood, paint, metal, concrete, cement, or

other masonry. This dust often contains chemicals known to cause cancer, birth defects, or other reproductive harm. Wear protective gear.

 

 

 

 

 

 

 

 

 

 

 

 

This product or its power

 

MANUAL

 

cord contains chemicals

 

 

 

known to the State of

 

 

 

California to cause cancer

and birth defects or other reproductive harm. Wash hands after handling.

This product is a part of a high pressure system and the following safety precautions must be followed at all times along with any other existing safety rules.

1.Read this instruction manual before installing this device on a compressed air system. Be thoroughly familiar with the controls and the proper use of the equipment.

2.Safety glasses must be worn during operation. Always work in a well ventilated area.

3.Do not exceed any pressure rating of any component in the system.

4.Protect air lines from damage and puncture.

5.Check air hoses for weak or worn condition before each use. Make sure all connections are secure.

6.Keep all nuts, bolts and screws tight and ensure equipment is in safe working condition.

This

product is

specifically designed for compressed air service ONLY. Use with any other fluid (liquid or gas) is a misapplication and not permitted. For example, use with or injection of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum gas) could be harmful to the unit or result in a combustable condition or hazardous external leakage. Campbell Hausfeld’s warranties are void in the event of misapplication and assumes no responsibility for any resulting loss.

Specifications

Maximum pressure: 150 PSIG (10 bar).

Maximum temperature: 125˚F (52˚C).

Installation

Disconnect power and

release all pressure from the system before attempting to install, service, relocate or perform any maintenance.

Service

Mounting Bracket

Indicator

 

Coalescing

Dryer

 

Filter

 

Figure 1

 

1.The air cleaner/dryer should be located as close as possible to the air tool or spray gun.

2.A shutoff valve should be installed before the air cleaner/dryer so the unit can be easily depressurized for servicing. Securely mount the air cleaner/dryer in a vertical position using the mounting bracket supplied with the unit.

3.Install a Campbell Hausfeld 3/8" Filter (PA212103) before and after the coalescing filter/dryer for optimum performance. Connect the piping or hose with airflow in the direction of the arrows cast into the top of the unit. Avoid using unnecessary fittings, couplings, etc., that restrict air flow.

4.Remove the bowl from the dryer housing by loosening the lock ring. Pull bowl down to remove from housing.

5.Open bag of desiccant and pour into bowl. Shake or tap bowl periodically to settle desiccant. Fill to within 1/2" from top of bowl. Do not allow desiccant to get into center tube.

6.Reinstall bowl on housing. Be sure the lock ring is tightened before pressurizing the unit.