Operating Instructions and Assembly Instructions

Airless Paint Sprayers

Cleanup for Changing Paints or Temporary Storage for More Than One Night

WEAR ALL NECESSARY

SAFETY GEAR Necessary Tools / Materials:

Pliers

Rag

Gloves

Two (2) buckets

At least one (1) gallon of cleaning fluid

Cleaning brush

NOTE: Do NOT disconnect any hoses.

NOTE: Refer to coating manufacturer for recommended cleaning fluid.

1.Turn prime/spray control to PRIME position.

2.Turn power switch to ON.

High pressure

hose may still be pressurized with prime/spray control in the PRIME position. With the gun pointed in a safe direction, pull the gun trigger to relieve any pressure in the hose.

3.Turn pressure to HIGH (completely clockwise).

4.Tilt unit back, lift suction assembly above fluid level in bucket.

While holding suction assembly above paint level, allow pump to run until empty.

5.Immediately place both suction assembly and bypass tube in a bucket containing enough cleaning fluid to cover suction bell by two inches. Allow pump to prime and begin circulating fluid.

6.While fluid is circulating, soak rag in fluid and wipe exterior of suction assembly and bypass tube. Remove suction filter with pliers. Wipe inside of suction filter housing with rag removing excess paint buildup. Clean both sides of suction filter with rag and reinsert filter into suction filter housing.

NOTE: Do NOT allow fluid to circulate for more than 15 minutes.

Cleaning Pump

1

Turn Prime/Spray

Control to PRIME

Position

3

Turn Pressure to HIGH (completely clockwise)

5

Suction Assembly and

Bypass Tube in Bucket

of cleaning fluid

2

Turn power switch to ON (shown in the OFF position)

4

Lift Suction Assembly above

Paint Level in Bucket

6

Wipe Exterior of Suction

Assembly and Bypass Tube

www.chpower.com