TECHNICAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

 

900 - 915mm

 

 

 

 

 

Width

 

 

1000mm

 

 

 

 

 

Depth

 

 

600mm (excluding door handles)

 

 

GENERAL

 

 

Rp /

 

(

/ ” BSP female)

 

 

 

 

 

Gas connection

 

 

 

 

 

 

 

 

 

 

1

 

2

1

2

 

 

 

 

 

 

Pressure test point

Hotplate burner injector

 

 

 

 

Gas rate adjustment

None

 

 

 

 

 

 

 

 

 

Aeration adjustment

None

 

 

 

 

 

 

 

 

 

Electrical connection

230/240V a.c. 50Hz.

 

 

 

 

 

Total electrical heat input

7.38 kW

 

 

 

 

 

 

 

 

240V a.c.

 

Cat II2H3+

 

 

 

Cat II2H3+

 

 

 

 

 

 

 

G30 at 28 - 30 mbar

 

 

 

G20 at 20 mbar

 

 

 

 

 

 

 

G31 at 37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNER

 

HEAT INPUT

HEAT

 

 

INJECTOR

 

HEAT

 

GAS RATE

INJECTOR

 

INPUT

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

2.0 kW

 

102

 

1.80 kW

 

130g/hr

65

Front Left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

3.0 kW

 

128

 

2.80 kW

 

205g/hr

82

Rear Left

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wok Inner

 

 

 

 

 

 

 

70

 

 

 

 

44

Centre Front

 

 

5.10 kW

 

 

 

4.75 kW

 

345g/hr

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wok Outer

 

 

 

 

 

 

 

2 x 114

 

 

 

 

 

2 x 70

Centre Front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

 

 

 

 

 

 

 

1.00 kW

 

 

 

 

Auxiliary

 

 

1.02 kW

 

72

 

 

75g/hr

50

Centre Rear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

1.65 kW

 

88

 

1.50 kW

 

110g/hr

60

Front Right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOTPLATE

 

 

1.65 kW

 

88

 

1.50 kW

 

110g/hr

60

Rear Right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWIN GRILL

 

2.66 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L/H OVEN

 

2.50 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/H OVEN

 

2.00 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARMING

 

0.22 kW

 

 

 

 

 

 

 

 

 

 

 

 

DRAWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28