Carrier 25HCR Install Liquid Line Filter Drier Indoor, Make Electrical Connections

Models: 25HCR

1 10
Download 10 pages 60.41 Kb
Page 6
Image 6
Install Liquid Line Filter Drier Indoor

IMPORTANT: Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment. Ensure tubes are not rubbing against each other or any sheet metal. Pay close attention to feeder tubes, makings sure wire ties on feeder tubes are secure and tight.

Be sure field wiring complies with local and national fire, safety, and electrical codes, and voltage to system is within limits shown on unit rating plate. Contact local power company for correction of improper voltage. See unit rating plate for recommended circuit protection device.

NOTE: Operation of unit on improper line voltage constitutes abuse and could affect unit reliability. See unit rating plate. Do not install unit in system where voltage may fluctuate above or below permissible limits.

 

 

!

CAUTION

25HCR

 

 

 

 

UNIT DAMAGE HAZARD

 

 

 

 

Failure to follow this caution may result in equipment

 

 

damage or improper operation.

 

 

Installation

of filter drier in liquid line is required.

 

 

 

 

 

 

Install Liquid Line Filter Drier Indoor

Refer to Fig. 7 and install filter drier as follows:

1.Braze 5 in. liquid tube to the indoor coil.

2.Wrap filter drier with damp cloth.

3.Braze filter drier to 5 in. long liquid tube from step 1.

4.Connect and braze liquid refrigerant tube to the filter drier.

A05227

Fig. 7 ---Liquid Line Filter Drier

STEP 8 Make Electrical Connections

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Do not supply power to unit with compressor terminal box cover removed.

NOTE: Use copper wire only between disconnect switch and unit.

NOTE: Install branch circuit disconnect of adequate size per NEC to handle unit starting current. Locate disconnect within sight from and readily accessible from unit, per Section 440-14 of NEC.

Route Ground and Power Wires

Remove access panel to gain access to unit wiring. Extend wires from disconnect through power wiring hole provided and into unit control box.

Connect Ground and Power Wires

Connect ground wire to ground connection in control box for safety. Connect power wiring to contactor as shown in Fig. 8.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes.

Connect ground wire to ground connection in control box for safety. Connect power wiring to contactor as shown in Fig. 8.

DISCONNECT￿

PER N. E. C. AND/OR￿

LOCAL CODES

CONTACTOR

FIELD POWER

WIRING

 

FIELD GROUND

 

WIRING

GROUND￿

 

 

LUG

A94025

Fig. 8 ---Line Connections