THERMIDISTAT
CONTROL
MODEL RH
HEAT STAGE 2 |
|
| O/W2 | |||
COOL STAGE 1 |
| Y1/W2 | ||||
| ||||||
|
|
|
| W/W1 | ||
HEAT STAGE 1 |
|
| ||||
|
| Y/Y2 | ||||
COOL STAGE 2 |
| |||||
|
|
|
|
|
|
|
FAN |
|
| G | |||
|
|
|
|
|
|
|
24 VAC HOT |
|
| R | |||
|
|
|
|
|
| |
DEHUMIDIFY |
| DHUM | ||||
|
|
|
|
|
| |
24 VAC COMM |
|
| C | |||
|
|
|
| HUM | ||
HUMIDIFY |
| |||||
|
|
|
|
| B | |
N/A |
|
| ||||
|
|
|
|
|
|
|
OUTDOOR |
|
|
| S1 | ||
SENSOR |
|
|
| S2 | ||
|
|
|
| |||
CONNECTION |
|
| ||||
|
|
|
|
|
|
|
CONDENSING | |
FURNACE | AIR CONDITIONER |
W2 |
|
| Y1 |
W/W1 |
|
Y/Y2 | Y2 |
G |
|
R | R |
DEHUM |
|
DE JUMPER |
|
C | C |
HUM |
|
HUMIDIFIER | |
(24 VAC) |
|
OUTDOOR |
|
SENSOR |
|
THERMIDISTAT
CONTROL
MODEL RH
HEAT STAGE 2 |
|
| O/W2 | ||
COOL STAGE 1 |
| Y1/W2 | |||
| |||||
HEAT STAGE 1 |
| W/W1 | |||
| |||||
COOL STAGE 2 |
|
| Y/ Y2 | ||
|
| ||||
|
|
|
|
|
|
FAN |
|
|
| G | |
|
|
|
|
|
|
24 VAC HOT |
|
|
| R | |
24 VAC COMM |
|
|
| C | |
|
|
| |||
N/A |
|
|
| ||
|
| DHUM | |||
HUMIDIFY |
|
| HUM | ||
|
| ||||
N/A |
|
|
| B | |
|
|
| |||
|
|
|
|
|
|
OUTDOOR |
|
| S1 | ||
SENSOR |
|
|
| S2 | |
|
|
| |||
CONNECTION |
|
| |||
|
|
|
|
|
|
| |
FURNACE |
|
WITH PSC | |
BLOWER MOTOR | AIR CONDITIONER |
W2 |
|
| Y1 |
W/W1 |
|
Y/Y2 | Y2 |
G |
|
R | R |
C | C |
HUMIDIFIER |
|
(24 VAC) |
|
OUTDOOR |
|
SENSOR |
|
|
|
|
|
|
|
|
|
|
|
|
| See notes 1, 2, 3, 6, 8, 10, and 12 |
|
|
|
|
|
|
|
|
|
|
|
| A01495 |
|
|
|
|
|
|
|
| |||||
THERMOSTAT | FK4C, FV4A | |||||||||||
MODEL 2S | OR 40FK | AIR CONDITIONER | ||||||||||
|
|
|
|
| FAN COIL |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| DH |
|
| J1 JUMPER | |
24 VAC HOT | R |
|
|
| R |
| R | |||||
24 VAC COMM | C |
|
|
| C |
| C | |||||
FAN | G |
|
|
| G |
|
| |||||
COOL STAGE 2 |
|
|
|
|
|
|
|
|
|
| ||
Y/Y2 |
|
|
| Y/Y2 |
|
| Y2 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
HEAT STAGE 1 | W/W1 |
|
|
|
| W1 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| REMOVE |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| J2 JUMPER |
HEAT STAGE 2 |
|
|
|
|
|
|
|
|
| FOR HEAT | ||
O/W2 |
|
|
|
| W2 |
| STAGING | |||||
COOL STAGE 1 | Y1 |
|
|
| Y1 |
| Y1 | |||||
N/A | B |
|
|
| O |
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||
OUTDOOR |
| S1 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||||
SENSOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CONNECTION |
| S2 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| See notes 1, 2, 3, 4, and 7 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A01496 |
THERMIDISTAT |
|
|
| ||||||||||||||
CONTROL |
|
|
| ||||||||||||||
| FURNACE | AIR CONDITIONER | |||||||||||||||
MODEL RH |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N/A |
| O/W2 |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Y1 |
|
COOL STAGE 1 |
| Y1/W2 |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HEAT STAGE 1 |
| W/W1 |
|
|
| W |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Y2 |
|
COOL STAGE 2 |
| Y/Y2 |
|
|
|
| Y |
|
|
|
|
| |||||
FAN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| G |
|
|
|
| G |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
24 VAC HOT |
|
| R |
|
|
|
| R |
|
|
|
|
|
| |||
24 VAC COMM |
|
|
|
|
|
|
| C |
|
|
| C |
| ||||
|
| C |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N/A |
| DHUM |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
HUMIDIFY |
| HUM |
|
| HUMIDIFIER |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| (24 VAC) |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
N/A |
|
| B |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| OUTDOOR |
|
|
|
| ||||
|
|
|
| S1 |
|
|
|
|
|
| |||||||
OUTDOOR |
|
|
|
|
| SENSOR |
|
|
|
| |||||||
SENSOR |
|
|
| S2 |
|
|
|
|
|
|
|
|
|
|
| ||
CONNECTION |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See notes 1, 2, 3, 6, 8, and 10
A01498
VARIABLE SPEED
80%
OAFS
THERMIDISTAT BOARD
| CONTROL |
|
|
|
|
| Y1 |
|
|
|
|
|
| |||||||||||
| MODEL RH |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
| FURNACE |
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
| COOL STAGE 1 | Y1/W2 |
|
|
|
|
| BOARD |
| AIR CONDITIONER | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HEAT STAGE 2 | O/W2 |
|
|
|
|
|
| W2 |
|
|
|
| Y1 |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HEAT STAGE 1 | W/ W1 |
|
|
|
|
|
| W/W1 |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Y2 |
| |
| COOL STAGE 2 | Y/ Y2 |
|
|
|
|
|
| Y/Y2 |
|
|
|
|
| ||||||||||
| FAN |
|
|
|
|
|
|
|
|
|
|
|
| G |
|
|
|
|
|
|
| |||
|
|
|
|
| G |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
|
| R |
| ||
| 24 VAC HOT |
| R |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C |
| |
| 24 VAC COM |
| C |
|
|
|
|
|
| COM |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HUM |
|
|
|
|
|
|
| ||
| DEHUMIDIFY | DHUM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| DEHUM |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| HUMIDIFY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| HUM |
|
|
|
|
|
| HUMIDIFIER |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (24 VAC) |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| N/A |
|
|
|
| B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| S1 |
|
|
|
|
|
|
| OUTDOOR |
|
|
|
|
|
| |||
| OUTDOOR |
|
|
|
|
|
|
|
|
|
| SENSOR |
|
|
|
|
|
| ||||||
| SENSOR |
|
|
| S2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| CONNECTIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| See notes 1, 2, 3, 6, 8, 10, and 11 | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A01499 | ||
|
| |||||||||||||||||||||||
THERMOSTAT |
|
|
|
| ||||||||||||||||||||
| MODEL 2S |
|
|
|
|
| FURNACE | AIR CONDITIONER | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
24 VAC HOT |
| R |
|
|
|
|
|
|
| R |
|
|
|
| R | |||||||||
24 VAC COMM |
| C |
|
|
|
|
|
|
| C |
|
|
|
| C | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
HEAT STAGE 1 | W/W1 |
|
|
|
|
|
| W |
|
|
|
|
|
|
| |||||||||
COOL STAGE 2 |
|
|
|
|
|
|
|
|
|
| Y |
|
|
|
|
|
|
|
| |||||
Y/Y2 |
|
|
|
|
|
|
|
|
|
|
| Y2 |
| |||||||||||
| FAN |
| G |
|
|
|
|
|
| G |
|
|
|
|
|
|
| |||||||
| N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| O/W2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
COOL STAGE 1 |
| Y1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Y1 |
| |||||||
| N/A |
| B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| S1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
OUTDOOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
SENSOR |
|
|
| S2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
CONNECTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See notes 1, 2, 3, 6, and 8
A01497See notes 1, 2, 3, and 5
A01500
Fig. 11—Typical 24V Wiring Diagram
6