Table 1D — 40RUA Physical Data, SI — Heat Pump Units

UNIT 40RUQ*

25

 

 

NOMINAL CAPACITY (kW)

70

 

 

OPERATING WEIGHT (kg)

 

Base Unit with TXV

326

Plenum

44

 

 

FANS

 

Qty...Diam. (mm)

2...381

Nominal Airflow (L/s)

3775

Airflow Range (L/s)

2831--- 4719

Nominal Motor kW (Standard Motor)

 

208/230---3---60 and 460---3---60

3.73

575---3---60

3.73

Motor Speed (r/s)

 

208/230---3---60 and 460---3---60

29.1

575---3---60

29.1

 

 

REFRIGERANT

R--- 410A

Operating charge (kg)

1.59/1.59

(approx per circuit){

DIRECT---EXPANSION COIL

Enhanced Copper Tubes, Aluminum Sine--- Wave Fins

Max Working Pressure (kPag)

4482

Face Area (sq m)

1.85

No. of Splits

2

No. of Circuits per Split

2

Split Type...Percentage

Face...50/50

Fins/m

591

 

 

PIPING CONNECTIONS,

 

Quantity...Size (in.)

 

DX Coil — Suction (ODF)

2...11/8

DX Coil — Liquid Refrigerant (ODF)

2...5/8

Steam Coil, In (MPT)

1...21/2

Steam Coil, Out (MPT)

1...11/2

Hot Water Coil, In (MPT)

1...2

Hot Water Coil, Out (MPT)

1...2

Condensate (PVC)

1...11/4 ODM/1 IDF

FILTERS

Throwaway — Factory Supplied

Quantity...Size (mm)

4...406 x 610 x 51

4...406 x 508 x 51

 

Access Location

Right or Left Side

 

 

STEAM COIL}

 

Max Working Pressure (kPag at 126° C)

138

Total Face Area (sq m)

1.24

Rows...Fins/m

1...394

 

 

HOT WATER COIL}

 

Max Working Pressure (kPag)

1034

Total Face Area (sq m)

1.24

Rows...Fins/m

2...335

Water Volume

 

(L)

52.6

(m3)

0.052

LEGEND

DX — Direct Expansion

TXV — Thermostatic Expansion Valve

{Units are shipped without refrigerant charge.

}Field installed accessory only.