The display scrolls the compartments which are activated in menu 7 (Compartment settings).

Remarks:

If there is a communication problem with the serial port of the refrigeration unit or if the refrigeration unit is switched off, the message “Unit connection lost” is displayed.

If the refrigeration unit is switched on but all compartments are switched off, the message “All compartments off” is displayed.

4 Parameter menu

The DataCold 500 T/R recorder has been designed to enable a multiple number of desired applications for individual customers. By using the corresponding parameter settings you can adjust the recorder functionality to the required needs. This chapter gives an overview and structure of the various parameters available.

To enter the parameter menu press the green button for 2 seconds. The display will show: "ENTER PIN code". The factory setting of the PIN code is 1111 but can be adjusted by the supervisor any time. (see menu 10.5)

Parameter Settings

 

ENTER PINCODE

 

1

2

****

4

3

After entering the correct PIN code you have access to the parameter menu’s and the first menu level is displayed. Select the desired menu with [<], [>] and press [edit] to enter one of the following parameter menu’s:

5.Temperature input settings

6.Digital inputs settings

7.Compartment settings

8.Alarm settings

9.Printer settings

10.General settings

11.Communications settings

5.Temperature inp. settings

↑ ↓ edit <-menu

Menu 5 : Temperature inputs settings

4 inputs for temperature measurement, you can switch on/off each input and assign a name depending on the sensor position. Standard input 1 is pre-set as „Return air“ and input 2 as „Rear“.

T1 Input

>on/off

If ‘on’, input 1 will be measured, displayed and stored into memory. Printing of input 1 is assigned in the compartment setting (menu 7). If ‘off’, go to menu 5.2.

5.1.1. Name

>Return air

You can select a sensor name from the table or enter a free text. (Free text is not translated when changing the language)

5.1.2. Name

>Free text

Enter a text as desired via the four buttons.

5.1.1Name Free text

<-cncl accept

↑ ↓ < >

T2 Input

>on/off. Menu structure as 5.1

 

 

Page 17

62-61138-20 (02/03)

Page 17
Image 17
Carrier 500 T/R user manual Parameter menu, Menu 5 Temperature inputs settings, T1 Input On/off, Return air