Carrier 500 T/R Menu Alarm settings, Alarm group On/off, FrozenChilledDryFree text, User menu

Models: 500 T/R

1 30
Download 30 pages 38.19 Kb
Page 20
Image 20
>+15°C >-30°C
>45 minute(s), delay time for alarm activating
>on/off, Menu structure as menu 8.1 >on/off, Menu structure as menu 8.1 >on/off, Menu structure as menu 8.1

Menu 8 :

Alarm settings

4 Alarm groups– each with a name to assign, upper- and lower temperature limit and a delay time. Each enabled alarm type can be activated by the user for any compartment, although per compartment only one alarm group can be set at the same time.

8.1

Alarm group 1

>on/off

 

8.1.1 Name

>Frozen>Chilled>Dry>Free text

You can select a pre-set alarm group from a list or enter a free text. (Free text is not translated when changing the language).

8.1.2 Upper limit 8.1.3 Lower limit 8.1.4 Delay time 8.2 Alarm group 2 8.3 Alarm group 3 8.4 Alarm group 4

Menu 9 : Printer settings

4 Alarm groups– each with a name to assign, upper- and lower temperature limit and a delay time. Each enabled alarm type can be activated by the user for any compartment, although per compartment only one alarm group can be set at the same time.

9.1

Graph upper limit

>+15°C

Upper limit for graphical print out

9.2

Graph lower limit

>-30°C

Lower limit for graphical print out

 

 

Attention : If the total temperature range between upper- and lower

 

 

limit is dividable by 9 you achieve a optimal result for a print out.

 

 

 

 

9.3

Graph scale (mm. per hr.)

>10 mm

A graphical print out consumes a lot of paper. This

 

 

 

parameter enables you to set the scaling of the print

 

 

 

out (mm of paper per hour). Set a value to avoid

 

 

 

wasting paper.

9.4

User menu

>Yes/No

If set to ‘Yes’ the following 4 parameters will be

 

 

 

available for the user in the print menu (see chapter

 

 

 

3.1 for detailed description).

9.5

Delivery ticket settings

 

Settings for the delivery ticket

 

 

 

(see chapter 3.1.5)

9.6

Print period setting

>10 Hour(s)

Set print period (see chapter 3.1.6)

9.7

Day start time (from)

>06:00

Set day start time for printing (see chapter 3.1.7)

9.8

Day end time (to)

>18:00

Set day end time (see chapter 3.1.8)