HPK-100 Installation and Operating Instructions Page 5 of 8

CP5060A 02/04/10

ELECTRICAL CONNECTIONS CONTINUED NOTE: Permanent disconnection of the vehicle horn is NOT recommended.
ADD PROPER FUSE
20A MAX.
12V
LAMP
YEL +VDC OUT
RED +VDC IN
BLK #22G -VDC FOR LAMP
LITE
SWITCH
RATED 15A @ 12VDC
HORN SELECT
SWITCH
RATED 15A @ 12VDC
ORG or RED #16G
BLU #16G
GRN #16G
Lite
OBSERVE
SWITCH TERMINAL
SPACING FOR
ORIENTATION
HORN
RELAY
+VDC
Vehicle
Horn
HORN
RELAY
CIRCUIT
Break
Connection
Splice
Splice
If the “HORN RELAY CIRCUIT” provides -
V
DC:
Connect “ORG or RED #16G” wire to +VDC supply
and connect “#16G BLK” to “HORN SELECT SWITCH”.
OBSERVE
SWITCH TERMINAL
SPACING FOR
ORIENTATION
SEE
WIRE SIZE TABLE
Recommended
Wire Size
Amps Size
5 - 10 #16G
10 - 15 #14G
Use next larger
size
if longer than 10 ft.
4-P Terminal Block Plug
(CP4688-04)
15A Automotive
Type Fuse
Plug into unit first for
terminal identification
Plug installed
this orientation
#18G BRN
#18G BRN
USE
WATERPROOF
BUTT CONNECTORS
FOR UNDER HOOD SPLICES
#16G BLK to -VDC
NEG
SP
K
SP
K
POS

UNDER HOOD

CSP-100B
SPEAKER
100W 11 ohm
#18G BRN
#18G WHT
Splice
Splice
ORG or RED #16G