OPTION SWITCHES

An internal 8-position DIP switch on the circuit board may be changed to select various options.

Accessing Option Switches - the DIP switch is located just behind the front panel of the ampli- fier. Use a 7/64” allen wrench to remove the 4 corner screws then remove front panel.

MMECH

A

N

AWAIL

U

TYELP

O

OUTPUT

LT1 LT2

PHSR HORN

SC-1002

REMOTE PANEL

OUTPUT POWER

 

 

HAND

LT2 LT1 HORN PHSR MECH YELP MAN AUTO LAMP NEG

CONTROL

 

SC-1000

Adjusting Option Switches - it is easiest to view the DIP

 

switch with the unit turned upside down. With the unit

ON

upside down, the DIP Switch is located on the internal

 

PCB assembly board toward the left side of the unit.

 

Switch 1 is toward the front of the unit. Switch ‘ON’ posi-

 

tion is toward the left side of the unit.

 

The default setting is shown here. Switch 1 is on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

SW-1 (AUX_P) Auxiliary Input Polarity - The auxiliary input is normally activated with positive. Turn switch off for negative activation.

SW-2 (INST_ON) Instant ON - The Enable input wiring is normally required to turn on the unit. Turning this switch on allows the front panel switches to instantly turn on the unit.

(SC-1002 and SC-1012 only)

SW-3(T-T)Two-Tone- Turn this switch on to replace Phaser with Two-Tone.

SW-4 (H_I) Horn Inhibit - Turn this switch on to disable Horn tone. Horn will be replaced with Yelp.

SW-3 and 4 Tone Disable - All siren tones may be disabled except Manual, Wail and Yelp by turning on both switches. Mechanical will be replaced with Wail. Phaser and Horn will be re- placed with Yelp.

SW-5 (HRC) Horn Ring Cycler 2 (HRC2) - While the siren is in standby, the auxiliary input can cycle through Mechanical, Wail, Yelp, and Phaser tones by repeatedly activating the auxiliary input. Turn this switch on for HRC2 feature. See OPERATION section for further details.

SW-6 (SM) Short Manual - The Manual siren tone will normally fall and die out when released. Turn this switch on to have Manual stop immediately.

SW-7 (MECH2) Mechanical Tone 2 - Turn this switch on for a different mechanical tone sound.

SW-8 (FALL) Mechanical Fall - Turn this switch on for a quicker mechanical tone fall time.

CP4997B

2/20/08

Page 5