METROPOLITAN

HANGING THE FAN

Step 3. To hang the fan body in the canopy, hold the fan body firmly and in- sert the nylon ball into the canopy opening. Check that no wires were pinched. Rotate the fan body until the slot in the nylon ball fits into the pin opposite the canopy opening.

BALL

SLOT

PIN

CANOPY ELECTRICAL CONNECTIONS

Step 4. Attach the fan wires to the ceiling fixture outlet box wiring by twisting the bare ends of the wires together and then securing with a wire nut. Test that the connection is secure by pulling on the wire nut. Connect in this order:

Electrical Connections

GREEN leads from mounting plate and fan to GROUND conductor of power source. Secure with wire nut.

WHITE wire from fan to white NEUTRAL wire in ceil- ing fixture outlet box. Secure with wire nut.

BLACK power wire from fan to BLACK power wire in ceiling outlet box. Secure with wire nut.

2 BLACK WIRES

2 WHITE WIRES

3 GREEN WIRES

WIRE NUT

CANOPY HATCH INSTALLATION

Step 5. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening.

Step 6. Install canopy hatch with the last canopy screw and lock washer. To do this, tilt the fan body away from the hatch opening.

Tighten the screws firmly by hand only,

Step 7. Straighten the fan, then check to ensure that there is no movement be- tween the canopy and ceiling or Hang-Tru ball and top support shaft.

CANOPY

HATCH

LOCK

WASHER

CANOPY

SCREW

Note: Write down the Serial Number and the model number for future reference.