USER’S GUIDE 2412

IR Mode

Use the IR Mode to exchange data between two watches or between your watch and computer, or some other device.

The following shows compatibility of data communication between this watch and other CASIO Wrist Camera Models.

Wrist Camera Model

Communication with this watch

 

 

WQV-3 series (Module 2411)

Supported

 

 

WQV-1/WQV-2 series

Not supported (different protocol)

(Module 2220)

 

 

 

Note

An infrared adapter or an IR port is required to exchange data with this watch.

 

6. On the sending watch, press F to send the

 

displayed image.

 

The data send screen shown nearby appears

SEND

while an image send operation is in progress.

The message OK appears momentarily after the

 

image send operation is complete. Next, the

 

watch returns to the send menu.

 

Pressing A during the above procedure displays

 

the COM. MENU screen.

After you are finished sending images, press D to return to the Timekeeping Mode.

OK

SEND

The following procedure covers data communication between two watches only. See the CD-ROM that comes with the watch and the documentation that comes with the infrared adapter for information about data communication with a computer.

Exchanging Data Between Two Watches

15 degree maximum

10cm (4 inches) maximum

To exchange data between two watches, orient the watches as shown above.

The 10cm (4 inches) and 30-degree maximums shown in the above

illustration apply only when the watches are pointed straight at each other.

The maximum allowable distance may be less if either watch is at an angle

(not pointed straight).

At an angle of 15 degrees or more, you may need to move the two watches

To receive an image

SEND

RECEIVE

Communication Errors

1.On the COM. MENU screen, use B or E to select watch ( ).

2.Press F to display the watch-to-watch send menu.

3.Press E to display the watch-to-watch receive menu.

Pressing B returns to the watch-to-watch send menu.

4.Press F to enter receive standby.

5.Align the IR ports of the two watches with each other, and perform the send operation on the sending watch.

See “To send an image” for more information.

The message OK appears momentarily, followed by the received image. Next, the watch returns to the receive menu.

Pressing A during the above procedure displays the COM. MENU screen.

After you are finished receiving images, press D to return to the Timekeeping Mode.

very close to each other.

To enter the IR Mode

In the Timekeeping Mode, press D twice to enter the IR Mode.

An initial screen appears for about one second, followed by the COM. MENU screen.

PCWatch

Screen messages appear in the IR Mode to let you know when there is a problem with data communication. When this happens, check the following to find out what you need to do. Also, you can avoid data communication problems by carefully observing the advice under “Communication Precautions”.

Communication Screen Messages

COM1‰:58

After about

COM.MENU

one second

 

 

INFRARED

 

 

INFRARED

 

 

 

 

 

 

Portable game device

Other (PDA, etc.)

ERROR SEND

(Sender),

ERROR RECEIVE

(Receiver)

MEMORY FULL

SEND

RECEIVE

Data send or receive failed for some reason. Try again.

Memory of the receiver is full. Delete data you no longer need and try again.

Something is interfering with proper data communication. Correct the cause of the problem. If data communication is not restored within about 25 seconds, ERROR appears on the display.

To send an image

COM.MENU

SEND

RECEIVE

SEND

2‰‰1. 6.3‰.P1‰:58

1.On the COM. MENU screen, use B or E to select watch ( ).

2.Press F to display the watch-to-watch send menu.

3.Press C to display the image selection screen.

Each press of C toggles between the image and the send menu.

The watch automatically returns to the send menu if you leave an image on the display for about five seconds.

4.Use E(+) and B (–) to scroll through the images and display the one you want to send.

SEND is displayed in the upper left corner of the image screen.

You can send only one image at a time between watches.

5.Align the IR ports of the two watches with each other.

Put the receiving watch into receive standby at this time. See “To receive an image” for more information.

(Sender) (Receiver)

Other Messages

CHECKING DATA

This message appears when an image is being

 

processed after data is received.

 

 

REC ERROR

Data cannot be saved because some problem

 

occurred while accessing flash memory.

 

 

Communication Precautions

The two IR ports must be within 10cm (4 inches) and 30 degrees of each other.

Proper data communication may also be impossible if the two IR ports are too close to each other.

At an angle of 15 degrees or more, you may need to move the two IR ports very close to each other.

Do not move the watch while communication is in progress.

Make sure there is nothing between the two IR ports that blocks the path of the IR signal.

Infrared communication may not be possible in areas where lighting is bright, near a window, etc.

In the case of inverter fluorescent lighting or other very strong light, try turning off the light or move to an area where light is not shining directly onto the infrared ports.

An unrelated nearby IR data communication operation can interfere with proper IR data communication.

The maximum allowable distance between the IR ports may be less than 10cm when watch battery power is low.

The watch automatically returns to the COM. MENU screen about five minutes after the image selection screen or receive standby screen is displayed. If the point where five minutes elapse occurs while a data send/ receive operation is in progress, the operation continues until it is complete, after which the watch automatically returns to the COM. MENU screen.

5

Page 5
Image 5
Casio 2412 manual IR Mode