5. Quality References

5. Quality References

This chapter will describe about references of the DT-X11 and its dedicated options concerned with environmental performance, compliance, mechanical and electric durability, etc.

5.1

 

Environmental Performances

 

5.1.1

DT-X11

 

 

 

 

 

Table 5.1

 

 

 

 

 

 

 

 

Item

 

 

Specification

Condition

 

Temperature

 

 

 

 

 

 

 

DT-X11M30RC

 

Operation

 

-20 ºC to 50 ºC

0 to 40 ºC for charging

 

 

 

DT-X11M30E

 

 

 

 

battery pack

 

 

 

DT-X11M30U

 

Non-operation

-20 ºC to 70 ºC

 

 

 

 

DT-X11M10RC

 

Operation

 

-10 ºC to 50 ºC

0 to 40 ºC for charging

 

 

 

DT-X11M10E

 

 

 

 

battery pack

 

 

 

 

 

 

Non-operation

-20 ºC to 60 ºC

 

 

Humidity

 

 

 

 

 

 

 

 

 

 

Operation

 

10 % to 80 %RH

No condensation

 

 

 

 

 

 

Non-operation

5 % to 90 %RH

 

 

Dust and water-splash proof

 

 

 

 

 

 

 

 

 

 

 

IP54 level, compliant with IEC60529 standard

 

Storage in carton box

 

 

 

 

 

 

 

 

 

 

Temperature

-10 ºC to 50 ºC

 

 

 

 

 

 

 

Humidity

 

90 %RH (Maximum)

 

5.1.2 DT-160IOE/DT-169CHGE

 

 

Table 5.2

 

 

 

 

 

 

 

 

Item

 

 

Specification

Condition

 

Temperature

 

 

 

 

 

 

 

 

Operation

 

0 ºC to 40 ºC

 

 

 

 

 

Storage

 

-10 ºC to 50 ºC

 

 

Humidity

 

 

 

 

 

 

 

 

Operation

 

30 % to 80 %RH

No condensation

 

 

 

 

Storage

 

30 % to 90 %RH

 

 

Storage in carton box

 

 

 

 

 

 

 

 

Temperature

-10 ºC to 50 ºC

 

 

 

 

 

Humidity

 

30 % to 90 %RH

No condensation